Airavattek Core PEM electrolyser stack and BOP, offered in 4 hydrogen output options from 10 Nm3/h to 250 Nm3/h. Design: safe shutdown on gas or pressure fault, modular skid for plug-in expansion and remote diagnostics. Used by refinery hydrogen, mobility fuelling stations and steel and fertiliser. Designed and tested to ISO 22734, IS 17565 and IEC 60079-10-1. Lead time 30-40 weeks; delivers to South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Airavattek
- Model
- AIR-6C3 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 30-40 weeks
- Warranty
- 24 months
- Standards
- ISO 22734, IS 17565, IEC 60079-10-1
- Delivers to
- South India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Hydrogen output10 Nm3/hAIR-6C3-01 | Hydrogen output: 10 Nm3/h | 1 nos · 30-40 weeks | on quote |
| Hydrogen output50 Nm3/hAIR-6C3-02 | Hydrogen output: 50 Nm3/h | 1 nos · 30-40 weeks | on quote |
| Hydrogen output100 Nm3/hAIR-6C3-03 | Hydrogen output: 100 Nm3/h | 1 nos · 30-40 weeks | on quote |
| Hydrogen output250 Nm3/hAIR-6C3-04 | Hydrogen output: 250 Nm3/h | 1 nos · 30-40 weeks | on quote |
Specifications
| Hydrogen output | 10 Nm3/h to 250 Nm3/h (see variants) |
|---|---|
| Technology | AEM |
| Operating pressure | 30 bar |
| H2 purity | 99.999% |
| Specific energy | 4.5 kWh/Nm3 |
| Turndown | 20-100%made to order: 10-100% |
| Electrolyte | Deionised water |
| Input power | 415 V ACmade to order: 6.6 kV AC / 11 kV AC |
| Water consumption | 1 L per Nm3 |
| Cooling | Air-cooledmade to order: Water-cooled |
| Hazardous area rating | Zone 2 IIC T1 |
| Control | PLC with SCADA interface |
| Stack life | 60000 hours |