Catalogue / Aspirating smoke detection
Air-sampling smoke detector, Eco seriesSample
by Ajanta Fire Engineers (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Ajanta Fire Engineers (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Ajanta Eco air-sampling smoke detector, offered in 5 coverage options from Up to 250 m² / 1 pipe to Up to 4000 m². Design: dust-immune with laser detection, four alarm levels for graded response and integration with gas suppression panel. Typically used for battery energy storage containers, data centres and control rooms and cable tunnels and galleries. Designed and tested to EN 54-20, NFPA 76 and NFPA 72. Lead time 6-8 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Ajanta
- Model
- AJA-F03 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 6-8 weeks
- Warranty
- 24 months from supply
- Standards
- EN 54-20, NFPA 76, NFPA 72
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| CoverageUp to 250 m² / 1 pipeAJA-F03-01 | Coverage: Up to 250 m² / 1 pipe | 2 nos · 6-8 weeks | for verified buyers |
| CoverageUp to 500 m² / 2 pipesAJA-F03-02 | Coverage: Up to 500 m² / 2 pipes | 2 nos · 6-8 weeks | for verified buyers |
| CoverageUp to 1000 m² / 4 pipesAJA-F03-03 | Coverage: Up to 1000 m² / 4 pipes | 2 nos · 6-8 weeks | for verified buyers |
| CoverageUp to 2000 m²AJA-F03-04 | Coverage: Up to 2000 m² | 2 nos · 6-8 weeks | for verified buyers |
| CoverageUp to 4000 m²AJA-F03-05 | Coverage: Up to 4000 m² | 2 nos · 6-8 weeks | for verified buyers |
Specifications
| Coverage | Up to 250 m² / 1 pipe to Up to 4000 m² (see variants) |
|---|---|
| Sensitivity | Class Cmade to order: Class A (very high) / Class B |
| Detection | Laser light scattering |
| Alarm levels | Alert, Action, Fire 1, Fire 2 |
| Pipe network | Up to 400 mmade to order: Up to 100 m |
| Sampling holes | Up to 40 |
| Airflow monitoring | Yes, with fault alarm |
| Relays | 5 |
| Communication | RS-485 |
| Power supply | 24 VDC |
| Dust filter | Replaceable |
| Operating temperature | -10 to 39 °C |
| Approval | EN 54-20 |