Meter calibration test system from Ajanta, Smart 8 series: 6 capacity options between Portable site tester 0.1S and 3-ph 12-position 0.02. Highlights: NABL-traceable reference standard, automatic meter testing with pass/fail report and barcode reading of meter serial numbers. Suited to meter reading and billing data download, meter manufacturers acceptance testing and discom meter testing laboratories. Designed and tested to IS 14697, IEC 62052-11 and IEC 62053-21. Lead time 4-6 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Ajanta
- Model
- AJA-047 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 4-6 weeks
- Warranty
- 12 months from supply
- Standards
- IS 14697, IEC 62052-11, IEC 62053-21
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| CapacityPortable site tester 0.1SAJA-047-01 | Capacity: Portable site tester 0.1S | 2 nos · 4-6 weeks | for verified buyers |
| CapacitySingle-phase 6-positionAJA-047-02 | Capacity: Single-phase 6-position | 2 nos · 4-6 weeks | for verified buyers |
| CapacitySingle-phase 12-positionAJA-047-03 | Capacity: Single-phase 12-position | 2 nos · 4-6 weeks | for verified buyers |
| Capacity3-ph 3-position 0.05AJA-047-04 | Capacity: 3-ph 3-position 0.05 | 2 nos · 4-6 weeks | for verified buyers |
| Capacity3-ph 6-position 0.05AJA-047-05 | Capacity: 3-ph 6-position 0.05 | 2 nos · 8-10 weeks | for verified buyers |
| Capacity3-ph 12-position 0.02AJA-047-06 | Capacity: 3-ph 12-position 0.02 | 2 nos · 8-10 weeks | for verified buyers |
Specifications
| Capacity | Portable site tester 0.1S to 3-ph 12-position 0.02 (see variants) |
|---|---|
| Reference accuracy | 0.05% |
| Voltage range | 57.7-480 V |
| Current range | 0.001-120 A |
| Source type | Programmable electronic source |
| Positions | 12 |
| Pulse input | Optical + LED/impulse |
| Test functions | Accuracy, starting current, no-load, constant |
| Software | Windows with report generation |
| Communication with meter | Optical probe, DLMS |
| Traceability | NABL calibration certificate |
| Supply | 230 V, 50 Hz |