Catalogue / SCADA, RTU & plant controllers
Solar plant controller (PPC), Neo seriesSample
by Ajanta SCADA Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Ajanta SCADA Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Neo range of solar plant controller (PPC) by Ajanta covers 4 i/O capacity options (64 DI / 32 DO / 16 AI to 512 I/O modular). Key features: local HMI for status and alarms, secure communication with TLS and role-based access and sequence of events recording at 1 ms resolution. Typically used for utility distribution automation, industrial captive substations and grid substation automation. Designed and tested to IEC 60870-5-104, IEC 61850 and IEC 60255. Lead time 4-6 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Ajanta
- Model
- AJA-3C3 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 4-6 weeks
- Warranty
- 24 months from commissioning
- Standards
- IEC 60870-5-104, IEC 61850, IEC 60255
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| I/O capacity64 DI / 32 DO / 16 AIAJA-3C3-01 | I/O capacity: 64 DI / 32 DO / 16 AI | 5 nos · 4-6 weeks | for verified buyers |
| I/O capacity128 I/O modularAJA-3C3-02 | I/O capacity: 128 I/O modular | 5 nos · 4-6 weeks | for verified buyers |
| I/O capacity256 I/O modularAJA-3C3-03 | I/O capacity: 256 I/O modular | 5 nos · 8-10 weeks | for verified buyers |
| I/O capacity512 I/O modularAJA-3C3-04 | I/O capacity: 512 I/O modular | 5 nos · 8-10 weeks | for verified buyers |
Specifications
| I/O capacity | 64 DI / 32 DO / 16 AI to 512 I/O modular (see variants) |
|---|---|
| Protocols | IEC 60870-5-101/104made to order: IEC 61850 server / Modbus RTU/TCP / DNP3 |
| CPU | ARM Cortex-A9 |
| Power supply | 110-220 VDC/VAC |
| Operating temperature | -25 to 70 °C |
| Analog input | 4-20 mAmade to order: 0-10 V / CT/PT direct |
| Ethernet ports | 2made to order: 4 with redundancy (PRP/HSR) |
| Serial ports | 4 x RS-232/485made to order: 2 x RS-485 |
| Time sync | SNTP |
| Event resolution | 1 ms SOE |
| Redundancy | Hot standby CPUmade to order: Single CPU |
| Mounting | DIN rail |
| Ingress protection | IP30 |