Catalogue / Gas-insulated switchgear (GIS)
Compact GIS bay for substation, Ultra 7 seriesSample
by Amaravatianant Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Amaravatianant Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Amaravatianant Ultra 7 compact GIS bay for substation, offered in 5 system voltage options from 36 kV to 420 kV. Design: UHF partial discharge sensors, maintenance-free enclosed design and factory-assembled bays. Suited to renewable pooling stations, industrial plants and metro rail traction. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 20-28 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Amaravatianant
- Model
- AMA-7A8 series
- Listing type
- Product
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- 20-28 weeks
- Warranty
- 24 months
- Standards
- IEC 62271-203, IEC 62271-1, IEC 62271-100
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- Door delivery in metro cities
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVAMA-7A8-01 | System voltage: 36 kV | 1 bay · 20-28 weeks | for verified buyers |
| System voltage72.5 kVAMA-7A8-02 | System voltage: 72.5 kV | 1 bay · 20-28 weeks | for verified buyers |
| System voltage145 kVAMA-7A8-03 | System voltage: 145 kV | 1 bay · 20-28 weeks | for verified buyers |
| System voltage245 kVAMA-7A8-04 | System voltage: 245 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage420 kVAMA-7A8-05 | System voltage: 420 kV | 1 bay · 40-52 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 420 kV (see variants) |
|---|---|
| Rated current | 2500 A |
| Short-circuit current | 40 kA |
| Configuration | Single bus |
| Enclosure | Aluminium alloy |
| Gas | SF6/N2 mixmade to order: SF6 / Clean air |
| Bay width | 1200 mm |
| Operating mechanism | Spring |
| Partial discharge monitoring | UHF sensors |
| Control | Local control cubicle with BCU |
| Gas leakage | < 0.1% per year |
| Earth switches | Maintenance + fast acting |
| Interlocks | Mechanical and electrical |