Catalogue / Testing & commissioning
Protection relay testing and settings, Volt seriesSample
by Arcmark Infra Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Arcmark Infra Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Volt service of protection relay testing and settings by Arcmark covers 6 plant capacity options (1 MW to 100 MW). Key features: test formats agreed before mobilisation, handover training to O&M team and thermography of terminations before charging. Used by repowering projects, lender completion tests and DISCOM and STU charging. Delivered in line with IEC 62446-1, IEC 61724-1 and CEA (Technical Standards for Connectivity) Regulations. Mobilisation 1-2 weeks on site; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Arcmark
- Model
- ARC-A88 series
- Listing type
- Service
- Unit
- MW
- Minimum order
- 1 MW
- Lead time
- 1-2 weeks on site
- Warranty
- Retest at no cost if failure traced to test error
- Standards
- IEC 62446-1, IEC 61724-1, CEA (Technical Standards for Connectivity) Regulations
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Plant capacity1 MWARC-A88-01 | Plant capacity: 1 MW | 1 MW · 1-2 weeks on site | on quote |
| Plant capacity5 MWARC-A88-02 | Plant capacity: 5 MW | 1 MW · 1-2 weeks on site | on quote |
| Plant capacity10 MWARC-A88-03 | Plant capacity: 10 MW | 1 MW · 1-2 weeks on site | on quote |
| Plant capacity25 MWARC-A88-04 | Plant capacity: 25 MW | 1 MW · 1-2 weeks on site | on quote |
| Plant capacity50 MWARC-A88-05 | Plant capacity: 50 MW | 1 MW · Report in 7 days | on quote |
| Plant capacity100 MWARC-A88-06 | Plant capacity: 100 MW | 1 MW · Report in 7 days | on quote |
Specifications
| Plant capacity | 1 MW to 100 MW (see variants) |
|---|---|
| Tests covered | Full plant functional and PR test |
| Instruments | Relay test set, thermal camera |
| Calibration | NABL traceable certificates |
| Team | Commissioning engineer plus 2 testers |
| Statutory support | CEIG inspection coordinationmade to order: DISCOM charging support |
| Reports | Commissioning dossier with as-builtmade to order: Test reports with signed formats |
| Duration on site | 5-7 daysmade to order: 10-14 days / 3-4 weeks |
| Performance guarantee test | Capacity and PR test per contract |
| Grid code checks | Not included |
| Payment | Milestone on energisation |