Register your company to see prices.

The Edge 8 range of station auxiliary transformer by Awadhakshay covers 6 rating options (50 kVA to 1600 kVA). Key features: low zero-sequence impedance, complete with neutral CT and links and limits fault current to relay-set value. Used by power plant station service, solar plant 33 kV systems and substation auxiliary supply. Designed and tested to IS 1180, IS 2026 and IEC 60076. Lead time 3-5 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Awadhakshay
Model
AWA-2C6 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
3-5 weeks
Warranty
24 months
Standards
IS 1180, IS 2026, IEC 60076
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Packaging
Drum / reel with end caps
Delivery terms
FOR nearest railhead
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Rating50 kVAAWA-2C6-01Rating: 50 kVA1 nos · 3-5 weeksfor verified buyers
Rating100 kVAAWA-2C6-02Rating: 100 kVA1 nos · 3-5 weeksfor verified buyers
Rating315 kVAAWA-2C6-03Rating: 315 kVA1 nos · 3-5 weeksfor verified buyers
Rating630 kVAAWA-2C6-04Rating: 630 kVA1 nos · 3-5 weeksfor verified buyers
Rating1000 kVAAWA-2C6-05Rating: 1000 kVA1 nos · 8-10 weeksfor verified buyers
Rating1600 kVAAWA-2C6-06Rating: 1600 kVA1 nos · 8-10 weeksfor verified buyers

Specifications

Rating50 kVA to 1600 kVA (see variants)
TypeStation servicemade to order: Earthing (zig-zag) / Auxiliary (Dyn11)
Primary voltage11 kVmade to order: 33 kV / 132 kV
Secondary voltage3.3 kVmade to order: 0.433 kV
Short-time rating10 smade to order: 30 s
Neutral current800 Amade to order: 200 A / 400 A
CoolingDry AN
Vector groupZNyn11made to order: Dyn11
ImpedanceLow zero-sequencemade to order: 4% / 5%
Tap changerOff-circuit +/- 5%
TerminationCable box
MountingPlinth
Neutral protectionCT on neutral