Common meter reading instrument (CMRI) from Awadh, Eco series: 3 capacity options between 3-ph 3-position 0.05 and 3-ph 12-position 0.02. Design: NABL-traceable reference standard, closed-loop source with high stability and automatic meter testing with pass/fail report. Suited to third-party testing labs, meter manufacturers acceptance testing and discom meter testing laboratories. Designed and tested to IS 14697, IEC 62052-11 and IEC 62053-21. Lead time 8-10 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Awadh
- Model
- AWA-E33 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 8-10 weeks
- Warranty
- 24 months from supply
- Standards
- IS 14697, IEC 62052-11, IEC 62053-21
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Capacity3-ph 3-position 0.05AWA-E33-01 | Capacity: 3-ph 3-position 0.05 | 2 nos · 8-10 weeks | for verified buyers |
| Capacity3-ph 6-position 0.05AWA-E33-02 | Capacity: 3-ph 6-position 0.05 | 2 nos · 8-10 weeks | for verified buyers |
| Capacity3-ph 12-position 0.02AWA-E33-03 | Capacity: 3-ph 12-position 0.02 | 2 nos · 8-10 weeks | for verified buyers |
Specifications
| Capacity | 3-ph 3-position 0.05 to 3-ph 12-position 0.02 (see variants) |
|---|---|
| Reference accuracy | 0.05%made to order: 0.1% / 0.02% |
| Voltage range | 57.7-480 V |
| Current range | 0.001-100 A |
| Source type | Programmable electronic source |
| Positions | 6made to order: 1 / 3 / 12 |
| Pulse input | Optical + LED/impulse |
| Test functions | Accuracy, starting current, no-load, constant |
| Software | Windows with report generation |
| Communication with meter | Optical probe, DLMS |
| Traceability | NABL calibration certificate |
| Supply | 230 V, 50 Hz |