Catalogue / Aspirating smoke detection

No photo yet

Aspirating smoke detection (ASD) unit, Volt seriesSample

by Beas Fire Engineers (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Beas Fire Engineers (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Aspirating smoke detection (ASD) unit from Beas, Volt series: 5 coverage options between Up to 250 m² / 1 pipe and Up to 4000 m². Design: integration with gas suppression panel, detects incipient fire at very low smoke densities and dust-immune with laser detection. Suited to battery energy storage containers, cable tunnels and galleries and data centres and control rooms. Designed and tested to EN 54-20, NFPA 76 and NFPA 72. Lead time 3-4 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Beas
Model
BEA-5C2 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
3-4 weeks
Warranty
24 months from supply
Standards
EN 54-20, NFPA 76, NFPA 72
Delivers to
East & North-East India
GST rate
18 %
Country of origin
India
Packaging
As per item, transit-safe
Delivery terms
Door delivery in metro cities
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
CoverageUp to 250 m² / 1 pipeBEA-5C2-01Coverage: Up to 250 m² / 1 pipe1 nos · 3-4 weeksfor verified buyers
CoverageUp to 500 m² / 2 pipesBEA-5C2-02Coverage: Up to 500 m² / 2 pipes1 nos · 3-4 weeksfor verified buyers
CoverageUp to 1000 m² / 4 pipesBEA-5C2-03Coverage: Up to 1000 m² / 4 pipes1 nos · 3-4 weeksfor verified buyers
CoverageUp to 2000 m²BEA-5C2-04Coverage: Up to 2000 m²1 nos · 6-8 weeksfor verified buyers
CoverageUp to 4000 m²BEA-5C2-05Coverage: Up to 4000 m²1 nos · 6-8 weeksfor verified buyers

Specifications

CoverageUp to 250 m² / 1 pipe to Up to 4000 m² (see variants)
SensitivityClass Cmade to order: Class A (very high) / Class B
DetectionLaser light scattering
Alarm levelsAlert, Action, Fire 1, Fire 2
Pipe networkUp to 400 mmade to order: Up to 100 m
Sampling holesUp to 40
Airflow monitoringYes, with fault alarm
Relays5
CommunicationRS-485
Power supply24 VDC
Dust filterReplaceable
Operating temperature-10 to 39 °C
ApprovalEN 54-20