The Eco range of DT health monitoring RTU by Beas covers 5 DT rating covered options (Up to 63 kVA to 1250-2000 kVA). Design: real-time loading and overload alarms, remote configuration of thresholds and power failure last-gasp message. Suited to discom energy audit, RDSS distribution loss reduction and transformer failure prevention. Designed and tested to IS 16444, IS 15959 and IEC 62053-22. Lead time 3-4 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Beas
- Model
- BEA-E76 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 10 nos
- Lead time
- 3-4 weeks
- Warranty
- 36 months from supply
- Standards
- IS 16444, IS 15959, IEC 62053-22
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- FOR nearest railhead
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| DT rating coveredUp to 63 kVABEA-E76-01 | DT rating covered: Up to 63 kVA | 10 nos · 3-4 weeks | for verified buyers |
| DT rating covered100-200 kVABEA-E76-02 | DT rating covered: 100-200 kVA | 10 nos · 3-4 weeks | for verified buyers |
| DT rating covered250-400 kVABEA-E76-03 | DT rating covered: 250-400 kVA | 10 nos · 3-4 weeks | for verified buyers |
| DT rating covered500-1000 kVABEA-E76-04 | DT rating covered: 500-1000 kVA | 10 nos · 6-8 weeks | for verified buyers |
| DT rating covered1250-2000 kVABEA-E76-05 | DT rating covered: 1250-2000 kVA | 10 nos · 6-8 weeks | for verified buyers |
Specifications
| DT rating covered | Up to 63 kVA to 1250-2000 kVA (see variants) |
|---|---|
| Measurement | V, I, kW, kVA, PF, THD |
| Accuracy class | 1.0made to order: 0.5S |
| CT input | CT 1000/1 Amade to order: Split-core CT 100/5 A / Split-core CT 600/5 A |
| Communication | NB-IoT |
| Oil temperature sensor | Not includedmade to order: PT100 with probe |
| Alarms | Overload, unbalance, phase failure, low voltage |
| Protocol | Modbusmade to order: MQTT / IEC 60870-5-104 |
| Data interval | 15 min |
| Power supply | Aux 230 Vmade to order: Self-powered from LT (3-ph) |
| Enclosure | IP65 polycarbonate |
| Load survey | 60 days internal |