Catalogue / Static VAR compensators (SVC)
Thyristor-switched capacitor (TSC) SVC, Elite 4 seriesSample
by Beas Power Electronics (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Beas Power Electronics (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Beas Elite 4 thyristor-switched capacitor (TSC) SVC, offered in 5 rating options from 2 MVAr to 40 MVAr. Highlights: supervisory SCADA integration, thyristor valve with redundant cooling and automatic filter switching and protection. Used by rolling mills, traction substations and arc and induction furnaces. Designed and tested to IEC 61954, IEC 60871 and IEEE 1031. Lead time 30-40 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Beas
- Model
- BEA-647 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 30-40 weeks
- Warranty
- 24 months from commissioning
- Standards
- IEC 61954, IEC 60871, IEEE 1031
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating2 MVArBEA-647-01 | Rating: 2 MVAr | 2 nos · 30-40 weeks | for verified buyers |
| Rating5 MVArBEA-647-02 | Rating: 5 MVAr | 2 nos · 30-40 weeks | for verified buyers |
| Rating10 MVArBEA-647-03 | Rating: 10 MVAr | 2 nos · 30-40 weeks | for verified buyers |
| Rating20 MVArBEA-647-04 | Rating: 20 MVAr | 2 nos · 30-40 weeks | for verified buyers |
| Rating40 MVArBEA-647-05 | Rating: 40 MVAr | 2 nos · 30-40 weeks | for verified buyers |
Specifications
| Rating | 2 MVAr to 40 MVAr (see variants) |
|---|---|
| System voltage | 11 kV |
| Configuration | TCR + FC |
| Thyristor valve | Air-cooledmade to order: Water-cooled |
| Response time | < 20 ms |
| Harmonic filters | 3rd, 5th, 7th, 11th |
| Control | Constant voltage, constant PF |
| Reactor | Dry-type air-core |
| Communication | IEC 60870-5-104 |
| Cooling | Forced airmade to order: Deionised water-glycol |
| Efficiency | > 99.2% |
| Operating range | Capacitive and inductive |