Aspirating smoke detection (ASD) unit from Betwa, Ultra series: 5 coverage options between Up to 250 m² / 1 pipe and Up to 4000 m². Design: remote configuration and event log, integration with gas suppression panel and fault-monitored pipe network and airflow. Typically used for high-bay warehouses, data centres and control rooms and cable tunnels and galleries. Designed and tested to EN 54-20, NFPA 76 and NFPA 72. Lead time 3-4 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Betwa
- Model
- BET-5C2 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 3-4 weeks
- Warranty
- 24 months from supply
- Standards
- EN 54-20, NFPA 76, NFPA 72
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| CoverageUp to 250 m² / 1 pipeBET-5C2-01 | Coverage: Up to 250 m² / 1 pipe | 5 nos · 3-4 weeks | for verified buyers |
| CoverageUp to 500 m² / 2 pipesBET-5C2-02 | Coverage: Up to 500 m² / 2 pipes | 5 nos · 3-4 weeks | for verified buyers |
| CoverageUp to 1000 m² / 4 pipesBET-5C2-03 | Coverage: Up to 1000 m² / 4 pipes | 5 nos · 3-4 weeks | for verified buyers |
| CoverageUp to 2000 m²BET-5C2-04 | Coverage: Up to 2000 m² | 5 nos · 6-8 weeks | for verified buyers |
| CoverageUp to 4000 m²BET-5C2-05 | Coverage: Up to 4000 m² | 5 nos · 6-8 weeks | for verified buyers |
Specifications
| Coverage | Up to 250 m² / 1 pipe to Up to 4000 m² (see variants) |
|---|---|
| Sensitivity | Class Bmade to order: Class A (very high) / Class C |
| Detection | Laser light scattering |
| Alarm levels | Alert, Action, Fire 1, Fire 2 |
| Pipe network | Up to 400 mmade to order: Up to 100 m |
| Sampling holes | Up to 40 |
| Airflow monitoring | Yes, with fault alarm |
| Relays | 5 |
| Communication | Modbusmade to order: RS-485 / Ethernet |
| Power supply | 24 VDC |
| Dust filter | Replaceable |
| Operating temperature | -10 to 39 °C |
| Approval | UL 268made to order: EN 54-20 |