Pressurised alkaline electrolyser plant, Ultra seriesSample
by Brahmaputraanant Hydrogen Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Brahmaputraanant Hydrogen Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Ultra range of pressurised alkaline electrolyser plant by Brahmaputraanant covers 5 hydrogen output options (50 Nm3/h to 1000 Nm3/h). Highlights: purity analyser with auto vent, safe shutdown on gas or pressure fault and dynamic operation with solar and wind input. Suited to green hydrogen plants, refinery hydrogen and glass and electronics. Designed and tested to ISO 22734, IS 17565 and IEC 60079-10-1. Lead time 16-24 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Brahmaputraanant
- Model
- BRA-256 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 10 nos
- Lead time
- 16-24 weeks
- Warranty
- 24 months
- Standards
- ISO 22734, IS 17565, IEC 60079-10-1
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- FOR nearest railhead
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Hydrogen output50 Nm3/hBRA-256-01 | Hydrogen output: 50 Nm3/h | 10 nos · 16-24 weeks | for verified buyers |
| Hydrogen output100 Nm3/hBRA-256-02 | Hydrogen output: 100 Nm3/h | 10 nos · 16-24 weeks | for verified buyers |
| Hydrogen output250 Nm3/hBRA-256-03 | Hydrogen output: 250 Nm3/h | 10 nos · 16-24 weeks | for verified buyers |
| Hydrogen output500 Nm3/hBRA-256-04 | Hydrogen output: 500 Nm3/h | 10 nos · 30-40 weeks | for verified buyers |
| Hydrogen output1000 Nm3/hBRA-256-05 | Hydrogen output: 1000 Nm3/h | 10 nos · 30-40 weeks | for verified buyers |
Specifications
| Hydrogen output | 50 Nm3/h to 1000 Nm3/h (see variants) |
|---|---|
| Technology | Alkaline |
| Operating pressure | 30 bar |
| H2 purity | 99.9%made to order: 99.999% |
| Specific energy | 4.5 kWh/Nm3made to order: 4.8 kWh/Nm3 / 5.2 kWh/Nm3 |
| Turndown | 10-100% |
| Electrolyte | 30% KOH |
| Input power | 6.6 kV AC |
| Water consumption | 1 L per Nm3 |
| Cooling | Air-cooled |
| Hazardous area rating | Zone 2 IIC T1 |
| Control | PLC with SCADA interface |
| Stack life | 80000 hoursmade to order: 60000 hours |