Catalogue / Mobile substations
Mobile GIS substation, Smart seriesSample
by Bundel Transformers (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Bundel Transformers (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Mobile GIS substation from Bundel, Smart series: 4 transformer rating options between 10 MVA and 50 MVA. Key features: compact oil spill containment, pre-wired and tested on a trailer and suitable for road transport within weight limits. Typically used for event power supply, discom emergency backup and maintenance outage support. Designed and tested to IEC 62271-202, IS 2026 and IEC 60076. Lead time 30-40 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Bundel
- Model
- BUN-7D3 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 30-40 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-202, IS 2026, IEC 60076
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- FOR nearest railhead
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Transformer rating10 MVABUN-7D3-01 | Transformer rating: 10 MVA | 5 nos · 30-40 weeks | for verified buyers |
| Transformer rating20 MVABUN-7D3-02 | Transformer rating: 20 MVA | 5 nos · 30-40 weeks | for verified buyers |
| Transformer rating31.5 MVABUN-7D3-03 | Transformer rating: 31.5 MVA | 5 nos · 30-40 weeks | for verified buyers |
| Transformer rating50 MVABUN-7D3-04 | Transformer rating: 50 MVA | 5 nos · 30-40 weeks | for verified buyers |
Specifications
| Transformer rating | 10 MVA to 50 MVA (see variants) |
|---|---|
| Primary voltage | 33 kV |
| Secondary voltage | 33 kV |
| Chassis | Low-bed trailermade to order: Skid / Container |
| Primary switchgear | AIS disconnector and breakermade to order: GIS bay |
| Secondary switchgear | Indoor VCB panel |
| Control and relay | Numerical relays |
| Fire protection | Detection and extinguisher |
| Auxiliary supply | DC battery + DG |
| Transport weight | Up to 45 t |
| Setup time | < 24 hoursmade to order: < 4 hours |
| Grounding | Mobile earthing kit |
| Cable reel | Included |