Catalogue / Testing & commissioning

No photo yet

Protection relay testing and settings, Core seriesSample

by Chola Consultants (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Chola Consultants (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Protection relay testing and settings from Chola, Core series: 3 plant capacity options between 1 MW and 10 MW. Design: thermography of terminations before charging, test formats agreed before mobilisation and live relay setting verification. Suited to EPC handover to owners, repowering projects and lender completion tests. Delivered in line with IEC 62446-1, IEC 61724-1 and CEA (Technical Standards for Connectivity) Regulations. Mobilisation 1-2 weeks on site; serves North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Chola
Model
CHO-A86 series
Listing type
Service
Unit
MW
Minimum order
1 MW
Lead time
1-2 weeks on site
Warranty
Retest at no cost if failure traced to test error
Standards
IEC 62446-1, IEC 61724-1, CEA (Technical Standards for Connectivity) Regulations
Delivers to
North India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Plant capacity1 MWCHO-A86-01Plant capacity: 1 MW1 MW · 1-2 weeks on sitefor verified buyers
Plant capacity5 MWCHO-A86-02Plant capacity: 5 MW1 MW · 1-2 weeks on sitefor verified buyers
Plant capacity10 MWCHO-A86-03Plant capacity: 10 MW1 MW · 1-2 weeks on sitefor verified buyers

Specifications

Plant capacity1 MW to 10 MW (see variants)
Tests coveredTransformer, switchgear, relay tests
InstrumentsCalibrated IV tracer, megger, CRMmade to order: Relay test set, thermal camera
CalibrationCalibration valid at test datemade to order: NABL traceable certificates
TeamLead plus 5 member crew
Statutory supportDISCOM charging supportmade to order: CEIG inspection coordination
ReportsCommissioning dossier with as-builtmade to order: Test reports with signed formats
Duration on site3-4 weeks
Performance guarantee testCapacity and PR test per contract
Grid code checksReactive power and ramp rate
Payment50% on start, 50% on reportmade to order: Milestone on energisation

BARREL: Bharat Atom Renewable Resources Energy Limited