Catalogue / Numerical relays

No photo yet

Busbar protection relay, Plus seriesSample

by Chola Power Controls (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Chola Power Controls (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Chola Plus busbar protection relay, offered in 6 function options from Overcurrent / earth fault to Busbar differential. Design: multiple setting groups, self-supervision with watchdog and breaker failure and trip circuit supervision. Typically used for industrial incomers, motor control centres and solar plant collector feeders. Designed and tested to IEC 60255, IEC 61850 and IS 3231. Lead time 3-6 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Chola
Model
CHO-9E1 series
Listing type
Product
Unit
nos
Minimum order
5 nos
Lead time
3-6 weeks
Warranty
24 months
Standards
IEC 60255, IEC 61850, IS 3231
Delivers to
All India
GST rate
18 %
Country of origin
India
Packaging
Wooden crate, seaworthy
Delivery terms
Ex-works, freight extra at actuals
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
FunctionOvercurrent / earth faultCHO-9E1-01Function: Overcurrent / earth fault5 nos · 3-6 weeksfor verified buyers
FunctionMotor protectionCHO-9E1-02Function: Motor protection5 nos · 3-6 weeksfor verified buyers
FunctionFeeder protectionCHO-9E1-03Function: Feeder protection5 nos · 3-6 weeksfor verified buyers
FunctionTransformer differentialCHO-9E1-04Function: Transformer differential5 nos · 3-6 weeksfor verified buyers
FunctionLine distanceCHO-9E1-05Function: Line distance5 nos · 8-10 weeksfor verified buyers
FunctionBusbar differentialCHO-9E1-06Function: Busbar differential5 nos · 8-10 weeksfor verified buyers

Specifications

FunctionOvercurrent / earth fault to Busbar differential (see variants)
Aux supply110 V DC
CT input1/5 A selectable
VT input110 V
Binary inputs32made to order: 8 / 16
Output relays24made to order: 6 / 12
CommunicationIEC 60870-5-103
DisplayLCD with keypadmade to order: Graphic LCD
Disturbance recorderUp to 100 records
Accuracy classClass 0.5 metering
CaseDraw-out
Time syncPTPmade to order: SNTP / IRIG-B
Cyber-securityRole-based access

BARREL: Bharat Atom Renewable Resources Energy Limited