Catalogue / Control & relay panels

No photo yet

Bus coupler panel, Neo seriesSample

by Chola Protection Systems (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Chola Protection Systems (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Bus coupler panel from Chola, Neo series: 5 system voltage options between 11 kV and 220 kV. Key features: trip circuit supervision and lockout relays, anti-condensation heater and facia annunciation with sequence of events. Suited to metro receiving substations, industrial HT substations and EHV substations. Designed and tested to IS 8623, IS 13947 and IEC 61439. Lead time 10-14 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Chola
Model
CHO-714 series
Listing type
Product
Unit
nos
Minimum order
2 nos
Lead time
10-14 weeks
Warranty
24 months
Standards
IS 8623, IS 13947, IEC 61439
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India (imported sub-assemblies)
Packaging
Steel skid with shrink wrap
Delivery terms
FOR nearest railhead
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
System voltage11 kVCHO-714-01System voltage: 11 kV2 nos · 10-14 weeksfor verified buyers
System voltage33 kVCHO-714-02System voltage: 33 kV2 nos · 10-14 weeksfor verified buyers
System voltage66 kVCHO-714-03System voltage: 66 kV2 nos · 10-14 weeksfor verified buyers
System voltage132 kVCHO-714-04System voltage: 132 kV2 nos · 10-14 weeksfor verified buyers
System voltage220 kVCHO-714-05System voltage: 220 kV2 nos · 10-14 weeksfor verified buyers

Specifications

System voltage11 kV to 220 kV (see variants)
Panel typeDuplex
Bay typeBus couplermade to order: Line / Transformer / Capacitor bank
ProtectionDifferential + REF
Panel size1000 x 800 x 2200 mm
ConstructionPowder-coated RAL 7035made to order: CRCA 2 mm sheet
Ingress protectionIP42made to order: IP31
MeteringDigital MFM
MimicLed mimic
Auxiliary supply220 V DC
CablingWired to TB with ferruling
AnnunciationWindows 16/24/32
TestingFAT with relay test set

BARREL: Bharat Atom Renewable Resources Energy Limited