Or send an open RFQ to every matching merchant.

Coromandelampere Max SF6 insulated compact RMU, offered in 6 configuration options from 2-way (LBS+LBS) to 5-way (3LBS+2VCB). Highlights: cable test facility on front panel, optional SCADA-ready motor operators and FPI and three-position switch prevents closing onto earth. Suited to residential and commercial campuses, urban 11 kV ring networks and discom compact substations. Designed and tested to IEC 62271-200, IEC 62271-103 and IEC 62271-105. Lead time 8-12 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Coromandelampere
Model
COR-993 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
8-12 weeks
Warranty
12 months from commissioning
Standards
IEC 62271-200, IEC 62271-103, IEC 62271-105
Delivers to
All India
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
FOR nearest railhead
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Configuration2-way (LBS+LBS)COR-993-01Configuration: 2-way (LBS+LBS)1 nos · 8-12 weekson quote
Configuration3-way (LBS+LBS+TF)COR-993-02Configuration: 3-way (LBS+LBS+TF)1 nos · 8-12 weekson quote
Configuration3-way (LBS+LBS+VCB)COR-993-03Configuration: 3-way (LBS+LBS+VCB)1 nos · 8-12 weekson quote
Configuration4-way (2LBS+LBS+VCB)COR-993-04Configuration: 4-way (2LBS+LBS+VCB)1 nos · 8-12 weekson quote
Configuration4-way (3LBS+TF)COR-993-05Configuration: 4-way (3LBS+TF)1 nos · 8-12 weekson quote
Configuration5-way (3LBS+2VCB)COR-993-06Configuration: 5-way (3LBS+2VCB)1 nos · 8-12 weekson quote

Specifications

Configuration2-way (LBS+LBS) to 5-way (3LBS+2VCB) (see variants)
Rated voltage24 kVmade to order: 12 kV / 36 kV
Rated current - ring630 A
Transformer feeder200 A fuse-switchmade to order: 630 A VCB
Short-circuit rating16 kA/3 s
Insulation mediumAir insulated
Switch typeDisconnector + earthing
ExtensibilityExtensible one side
Protection relayNumerical relay
Fault passage indicatorIncluded
EnclosureMild steel RAL 7035made to order: Stainless steel gas tank
Degree of protectionIP67 tank
Motor operatorNot fitted