Catalogue / Hybrid & dead-tank switchgear
Compact switching assembly, Eco seriesSample
by Coromandelphase Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Coromandelphase Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Eco range of compact switching assembly by Coromandelphase covers 4 system voltage options (72.5 kV to 420 kV). Key features: reduced foundation and civil work, seismic qualified and combines breaker, disconnector and CT. Used by pollution and coastal areas, seismic zones and brownfield bay additions. Designed and tested to IEC 62271-100, IEC 62271-108 and IEC 62271-1. Lead time 28-36 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Coromandelphase
- Model
- COR-CB5 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 28-36 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-100, IEC 62271-108, IEC 62271-1
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- FOR site, freight included
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage72.5 kVCOR-CB5-01 | System voltage: 72.5 kV | 5 nos · 28-36 weeks | for verified buyers |
| System voltage145 kVCOR-CB5-02 | System voltage: 145 kV | 5 nos · 28-36 weeks | for verified buyers |
| System voltage245 kVCOR-CB5-03 | System voltage: 245 kV | 5 nos · 28-36 weeks | for verified buyers |
| System voltage420 kVCOR-CB5-04 | System voltage: 420 kV | 5 nos · 28-36 weeks | for verified buyers |
Specifications
| System voltage | 72.5 kV to 420 kV (see variants) |
|---|---|
| Concept | Dead tank |
| Rated current | 4000 Amade to order: 2000 A / 3150 A |
| Breaking current | 50 kAmade to order: 31.5 kA / 40 kA |
| Gas | SF6-freemade to order: SF6 |
| Integrated CT | Yes, up to 5 cores |
| Integrated disconnector | Nomade to order: Yes |
| Integrated earth switch | Yes |
| Mechanism | Motor spring |
| Insulation | Air outdoor bushings |
| Footprint saving | 50-70% |
| Operating temp | -30 to 50 deg C |
| Monitoring | Gas density, operation counter |