Catalogue / Gas-insulated switchgear (GIS)
Single-phase encapsulated GIS, Smart seriesSample
by Coromandelphase Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Coromandelphase Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Smart range of single-phase encapsulated GIS by Coromandelphase covers 5 system voltage options (36 kV to 420 kV). Design: suitable for indoor and outdoor, factory-assembled bays and gas compartment with density monitors. Used by renewable pooling stations, metro rail traction and industrial plants. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 20-28 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Coromandelphase
- Model
- COR-D32 series
- Listing type
- Product
- Unit
- bay
- Minimum order
- 2 bay
- Lead time
- 20-28 weeks
- Warranty
- 24 months
- Standards
- IEC 62271-203, IEC 62271-1, IEC 62271-100
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- FOR nearest railhead
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVCOR-D32-01 | System voltage: 36 kV | 2 bay · 20-28 weeks | for verified buyers |
| System voltage72.5 kVCOR-D32-02 | System voltage: 72.5 kV | 2 bay · 20-28 weeks | for verified buyers |
| System voltage145 kVCOR-D32-03 | System voltage: 145 kV | 2 bay · 20-28 weeks | for verified buyers |
| System voltage245 kVCOR-D32-04 | System voltage: 245 kV | 2 bay · 40-52 weeks | for verified buyers |
| System voltage420 kVCOR-D32-05 | System voltage: 420 kV | 2 bay · 40-52 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 420 kV (see variants) |
|---|---|
| Rated current | 4000 A |
| Short-circuit current | 31.5 kAmade to order: 40 kA / 50 kA |
| Configuration | Single bus |
| Enclosure | Steel |
| Gas | Clean air |
| Bay width | 1200 mmmade to order: 800 mm / 2500 mm |
| Operating mechanism | Motor |
| Partial discharge monitoring | UHF sensors |
| Control | Local control cubicle with BCU |
| Gas leakage | < 0.1% per year |
| Earth switches | Maintenance + fast acting |
| Interlocks | Mechanical and electrical |