Catalogue / Thermography & condition monitoring

No photo yet

Predictive maintenance programme, Volt seriesSample

by Doaba Engineering Services (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Doaba Engineering Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Doaba Volt predictive maintenance programme, offered in 5 asset size options from 5 MW to 100 MW. Design: safe scanning without shutdown, load condition recorded with each scan and re-scan after repair included. Suited to wind turbine electrical systems, solar plants (module and string hotspots) and industrial MCC panels. Delivered in line with ISO 18434-1, IEC 62446-3 and IEEE 1584. Mobilisation Mobilisation in 3-7 days; serves West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Doaba
Model
DOA-793 series
Listing type
Service
Unit
site
Minimum order
1 site
Lead time
Mobilisation in 3-7 days
Warranty
Re-scan of repaired points at no cost
Standards
ISO 18434-1, IEC 62446-3, IEEE 1584
Delivers to
West India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Asset size5 MWDOA-793-01Asset size: 5 MW1 site · Mobilisation in 3-7 daysfor verified buyers
Asset size10 MWDOA-793-02Asset size: 10 MW1 site · Mobilisation in 3-7 daysfor verified buyers
Asset size25 MWDOA-793-03Asset size: 25 MW1 site · Mobilisation in 3-7 daysfor verified buyers
Asset size50 MWDOA-793-04Asset size: 50 MW1 site · Report in 5-10 daysfor verified buyers
Asset size100 MWDOA-793-05Asset size: 100 MW1 site · Report in 5-10 daysfor verified buyers

Specifications

Asset size5 MW to 100 MW (see variants)
TechniqueVibration analysis
Camera resolution1280x1024 radiometricmade to order: 640x480 radiometric
DeliverableCAT-wise severity ranking with fix actions
Drone servicesGround sampling 3 cm per pixel
Defect classificationDelta T based severity
TeamLevel II thermographer plus pilot
CertificationISO 18436-7 trained
TurnaroundReport in 10 daysmade to order: Report in 5 days
FrequencyOne-timemade to order: Annual or bi-annual plan
SoftwareAnalyser software with thermal library

BARREL: Bharat Atom Renewable Resources Energy Limited