Catalogue / Electrical safety audits
Safety audit for solar plants and substations, Prime seriesSample
by Dwaraka Projects (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Dwaraka Projects (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Prime service of safety audit for solar plants and substations by Dwaraka covers 5 installed load options (500 kVA to 25 MVA). Design: compliance matrix against CEA safety rules, photographic evidence of non-compliances and earthing health and soil resistivity. Suited to hospitals and commercial buildings, manufacturing plants and data centres. Delivered in line with Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations and IS 5216. Mobilisation Audit in 1-2 weeks; serves South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Dwaraka
- Model
- DWA-889 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Audit in 1-2 weeks
- Warranty
- Clarifications on report at no cost for 6 months
- Standards
- Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations, IS 5216
- Delivers to
- South India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Installed load500 kVADWA-889-01 | Installed load: 500 kVA | 1 site · Audit in 1-2 weeks | on quote |
| Installed load1 MVADWA-889-02 | Installed load: 1 MVA | 1 site · Audit in 1-2 weeks | on quote |
| Installed load5 MVADWA-889-03 | Installed load: 5 MVA | 1 site · Audit in 1-2 weeks | on quote |
| Installed load10 MVADWA-889-04 | Installed load: 10 MVA | 1 site · Report in 7-14 days | on quote |
| Installed load25 MVADWA-889-05 | Installed load: 25 MVA | 1 site · Report in 7-14 days | on quote |
Specifications
| Installed load | 500 kVA to 25 MVA (see variants) |
|---|---|
| Scope | Audit with arc-flash studymade to order: Visual and documentation audit / Audit with measurements |
| Auditor | CEA-licensed engineermade to order: Chartered engineer |
| Measurements | Thermography and power qualitymade to order: Earth resistance, insulation |
| Report | Action plan with timeline |
| Statutory records | Registers, test certificates, licencemade to order: Permit-to-work audit |
| Sampling | Representative LV panelsmade to order: 100% of HV equipment |
| Follow-up | Close-out verification |
| Turnaround | 3-4 weeks |
| Presentation | Report onlymade to order: Findings to management |
| Accreditation | Government recognised agency |