The Xtra 4 service of bushing and OLTC replacement by Garudatron covers 5 transformer rating options (10 MVA to 315 MVA). Design: nitrogen or dry air purge on opening, core insulation resistance checks and post-work tan delta and ratio tests. Used by industrial distribution transformers, solar and wind pooling substations and captive power plants. Delivered in line with IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance) and IEC 60422. Mobilisation Planned shutdown required; serves West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Garudatron
Model
GAR-619 series
Listing type
Service
Unit
nos
Minimum order
1 nos
Lead time
Planned shutdown required
Warranty
Oil quality guarantee 6 months
Standards
IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance), IEC 60422
Delivers to
West India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating10 MVAGAR-619-01Transformer rating: 10 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating20 MVAGAR-619-02Transformer rating: 20 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating50 MVAGAR-619-03Transformer rating: 50 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating100 MVAGAR-619-04Transformer rating: 100 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating315 MVAGAR-619-05Transformer rating: 315 MVA1 nos · Planned shutdown requiredfor verified buyers

Specifications

Transformer rating10 MVA to 315 MVA (see variants)
ServiceInternal inspection and overhaul
Filtration machineMobile 12000 L/hr
Oil BDV targetAbove 70 kVmade to order: Above 60 kV
Moisture targetBelow 5 ppmmade to order: Below 10 ppm
TestingFull routine tests after overhaulmade to order: DGA, furan, BDV, tan delta
SparesGaskets and silica gelmade to order: Bushings and OLTC parts at cost
Downtime3-4 weeks
Site workWorkshop repair
CrewSpecialised overhaul team
CertificateOverhaul report with test datamade to order: Oil test report from NABL lab