Catalogue / Earthing & auxiliary transformers
Dry-type auxiliary service transformer, Prime 5 seriesSample
by Godavari Power Transformers (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Godavari Power Transformers (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Godavari Prime 5 dry-type auxiliary service transformer, offered in 6 rating options from 100 kVA to 3150 kVA. Design: complete with neutral CT and links, provides earth reference to ungrounded systems and short-time rated for fault duty. Typically used for substation auxiliary supply, industrial networks and power plant station service. Designed and tested to IS 1180, IS 2026 and IEC 60076. Lead time 8-10 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Godavari
- Model
- GOD-A88 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 8-10 weeks
- Warranty
- 18 months
- Standards
- IS 1180, IS 2026, IEC 60076
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Corrugated box on pallet
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating100 kVAGOD-A88-01 | Rating: 100 kVA | 2 nos · 8-10 weeks | on quote |
| Rating315 kVAGOD-A88-02 | Rating: 315 kVA | 2 nos · 8-10 weeks | on quote |
| Rating630 kVAGOD-A88-03 | Rating: 630 kVA | 2 nos · 8-10 weeks | on quote |
| Rating1000 kVAGOD-A88-04 | Rating: 1000 kVA | 2 nos · 8-10 weeks | on quote |
| Rating1600 kVAGOD-A88-05 | Rating: 1600 kVA | 2 nos · 8-10 weeks | on quote |
| Rating3150 kVAGOD-A88-06 | Rating: 3150 kVA | 2 nos · 8-10 weeks | on quote |
Specifications
| Rating | 100 kVA to 3150 kVA (see variants) |
|---|---|
| Type | Earthing (zig-zag)made to order: Auxiliary (Dyn11) / Station service |
| Primary voltage | 11 kV |
| Secondary voltage | 0.433 kVmade to order: 3.3 kV |
| Short-time rating | 10 smade to order: 30 s |
| Neutral current | 200 Amade to order: 400 A / 800 A |
| Cooling | Dry ANmade to order: ONAN |
| Vector group | Dyn11 |
| Impedance | Low zero-sequencemade to order: 4% / 5% |
| Tap changer | Off-circuit +/- 5% |
| Termination | Cable box |
| Mounting | Plinthmade to order: Skid |
| Neutral protection | CT on neutral |