Catalogue / Thermography & condition monitoring

No photo yet

Predictive maintenance programme, Duo seriesSample

by Guptaphase Infra Services (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Guptaphase Infra Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Predictive maintenance programme from Guptaphase, Duo series: 3 asset size options between 25 MW and 100 MW. Highlights: trend data for repeated surveys, hotspot location tagged with GPS and priority list of defects with repair advice. Suited to solar plants (module and string hotspots), wind turbine electrical systems and substation switchgear and transformers. Delivered in line with ISO 18434-1, IEC 62446-3 and IEEE 1584. Mobilisation Report in 5-10 days; serves South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Guptaphase
Model
GUP-797 series
Listing type
Service
Unit
site
Minimum order
1 site
Lead time
Report in 5-10 days
Warranty
Re-scan of repaired points at no cost
Standards
ISO 18434-1, IEC 62446-3, IEEE 1584
Delivers to
South India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Asset size25 MWGUP-797-01Asset size: 25 MW1 site · Report in 5-10 daysfor verified buyers
Asset size50 MWGUP-797-02Asset size: 50 MW1 site · Report in 5-10 daysfor verified buyers
Asset size100 MWGUP-797-03Asset size: 100 MW1 site · Report in 5-10 daysfor verified buyers

Specifications

Asset size25 MW to 100 MW (see variants)
TechniqueHandheld thermographymade to order: Drone thermal imaging / Partial discharge testing / Vibration analysis
Camera resolution640x480 radiometric
DeliverableCAT-wise severity ranking with fix actions
Drone servicesGround sampling 3 cm per pixelmade to order: Orthomosaic of full plant
Defect classificationPer client maintenance policy
TeamLevel II thermographer
CertificationISO 18436-7 trainedmade to order: Technicians with ASNT level II
TurnaroundReport in 5 days
FrequencyAnnual or bi-annual planmade to order: One-time
SoftwareCloud dashboard with trend historymade to order: Analyser software with thermal library

BARREL: Bharat Atom Renewable Resources Energy Limited