Catalogue / Power system studies (load flow, short circuit, grid code)

No photo yet

Harmonic and power quality study, Prime seriesSample

by Hoysala Logistics (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Hoysala Logistics (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Prime service of harmonic and power quality study by Hoysala covers 3 network scale options (132 kV system to 400 kV system). Design: fault level verification of switchgear, PSS/E and PSCAD model support and relay setting files ready to load. Typically used for renewable developers seeking connectivity, BESS integrators and utilities and consultants. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation Kick-off in 1 week; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Hoysala
Model
HOY-4B2 series
Listing type
Service
Unit
report
Minimum order
1 report
Lead time
Kick-off in 1 week
Warranty
Revision for utility comments
Standards
CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Network scale132 kV systemHOY-4B2-01Network scale: 132 kV system1 report · Kick-off in 1 weekfor verified buyers
Network scale220 kV systemHOY-4B2-02Network scale: 220 kV system1 report · Kick-off in 1 weekfor verified buyers
Network scale400 kV systemHOY-4B2-03Network scale: 400 kV system1 report · Kick-off in 1 weekfor verified buyers

Specifications

Network scale132 kV system to 400 kV system (see variants)
Study typeHarmonicsmade to order: Load flow and short circuit / Dynamic and transient / Protection coordination
SoftwarePSS/E
Model dataUtility network model
DeliverablesModel files and relay settingsmade to order: Study report with results
Grid code checksVoltage and reactive power capabilitymade to order: LVRT/HVRT and ramp rate
ReviewLender review
ScenariosNormal and N-1
TeamLead plus modelling specialist
Turnaround4-6 weeksmade to order: 2-3 weeks
ValidationCompared with measured data

BARREL: Bharat Atom Renewable Resources Energy Limited