Catalogue / Hydrogen sensors & safety systems

No photo yet

Catalytic bead hydrogen gas detector, Xtra seriesSample

by Hoysala New Energy (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Hoysala New Energy (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Xtra range of catalytic bead hydrogen gas detector by Hoysala covers 4 detection range options (0-1000 ppm to 0-100% vol). Key features: ATEX / IECEx flameproof enclosure, interface with plant ESD and self-diagnostics and sensor fault alarm. Typically used for refineries, electrolyser plants and power plant generator hydrogen cooling. Designed and tested to IEC 60079-29-1, IEC 60079-0 and IEC 61508 (SIL 2). Lead time 6-8 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Hoysala
Model
HOY-AB1 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
6-8 weeks
Warranty
24 months
Standards
IEC 60079-29-1, IEC 60079-0, IEC 61508 (SIL 2)
Delivers to
All India
GST rate
18 %
Country of origin
India (imported sub-assemblies)
Packaging
Steel skid with shrink wrap
Delivery terms
Door delivery in metro cities
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Detection range0-1000 ppmHOY-AB1-01Detection range: 0-1000 ppm1 nos · 6-8 weeksfor verified buyers
Detection range0-4% volHOY-AB1-02Detection range: 0-4% vol1 nos · 6-8 weeksfor verified buyers
Detection range0-100% LELHOY-AB1-03Detection range: 0-100% LEL1 nos · 6-8 weeksfor verified buyers
Detection range0-100% volHOY-AB1-04Detection range: 0-100% vol1 nos · 6-8 weeksfor verified buyers

Specifications

Detection range0-1000 ppm to 0-100% vol (see variants)
Sensor typeElectrochemical
OutputModbus RTU
Response time T90< 30 smade to order: < 10 s
Accuracy+/- 2% of FS
Hazardous areaEx d IIC T4made to order: Ex ia IIC T4
Supply24 V DC
Ingress protectionIP66
HousingAluminiummade to order: SS 316
Operating temperature-40 to 70 deg C
Calibration interval12 months
Alarm set points10% LEL
Sensor life5 yearsmade to order: 3 years