Distance protection relay, Ultra seriesSample
by Hoysala Power Controls (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Hoysala Power Controls (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Ultra range of distance protection relay by Hoysala covers 6 function options (Overcurrent / earth fault to Busbar differential). Key features: graphical logic programming, breaker failure and trip circuit supervision and self-supervision with watchdog. Suited to transformer bays, industrial incomers and motor control centres. Designed and tested to IEC 60255, IEC 61850 and IS 3231. Lead time 8-10 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Hoysala
- Model
- HOY-F49 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 10 nos
- Lead time
- 8-10 weeks
- Warranty
- 24 months
- Standards
- IEC 60255, IEC 61850, IS 3231
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- FOR site, freight included
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| FunctionOvercurrent / earth faultHOY-F49-01 | Function: Overcurrent / earth fault | 10 nos · 8-10 weeks | for verified buyers |
| FunctionMotor protectionHOY-F49-02 | Function: Motor protection | 10 nos · 8-10 weeks | for verified buyers |
| FunctionFeeder protectionHOY-F49-03 | Function: Feeder protection | 10 nos · 8-10 weeks | for verified buyers |
| FunctionTransformer differentialHOY-F49-04 | Function: Transformer differential | 10 nos · 8-10 weeks | for verified buyers |
| FunctionLine distanceHOY-F49-05 | Function: Line distance | 10 nos · 8-10 weeks | for verified buyers |
| FunctionBusbar differentialHOY-F49-06 | Function: Busbar differential | 10 nos · 8-10 weeks | for verified buyers |
Specifications
| Function | Overcurrent / earth fault to Busbar differential (see variants) |
|---|---|
| Aux supply | 110 V DCmade to order: 24-250 V DC / 220 V DC |
| CT input | 1/5 A selectablemade to order: 1 A / 5 A |
| VT input | 63.5 V |
| Binary inputs | 32 |
| Output relays | 6made to order: 12 / 24 |
| Communication | IEC 60870-5-103 |
| Display | LCD with keypad |
| Disturbance recorder | Up to 100 recordsmade to order: Up to 20 records |
| Accuracy class | Class 0.5 metering |
| Case | Flush mount |
| Time sync | SNTP |
| Cyber-security | Role-based access |