Catalogue / Numerical relays

No photo yet

Distance protection relay, Pro seriesSample

by Jalcore Protection Systems (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Jalcore Protection Systems (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Pro range of distance protection relay by Jalcore covers 4 function options (Overcurrent / earth fault to Transformer differential). Key features: front USB and rear Ethernet ports, breaker failure and trip circuit supervision and event and fault recorder with 1 ms stamps. Used by substation feeders, transformer bays and industrial incomers. Designed and tested to IEC 60255, IEC 61850 and IS 3231. Lead time 3-6 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Jalcore
Model
JAL-F42 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
3-6 weeks
Warranty
24 months
Standards
IEC 60255, IEC 61850, IS 3231
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Packaging
Wooden crate, seaworthy
Delivery terms
Ex-works, freight extra at actuals
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
FunctionOvercurrent / earth faultJAL-F42-01Function: Overcurrent / earth fault1 nos · 3-6 weeksfor verified buyers
FunctionMotor protectionJAL-F42-02Function: Motor protection1 nos · 3-6 weeksfor verified buyers
FunctionFeeder protectionJAL-F42-03Function: Feeder protection1 nos · 8-10 weeksfor verified buyers
FunctionTransformer differentialJAL-F42-04Function: Transformer differential1 nos · 8-10 weeksfor verified buyers

Specifications

FunctionOvercurrent / earth fault to Transformer differential (see variants)
Aux supply110 V DCmade to order: 24-250 V DC / 220 V DC
CT input1 A
VT input110 V
Binary inputs16
Output relays24made to order: 6 / 12
CommunicationModbusmade to order: IEC 61850 Ed 2 / IEC 60870-5-103
DisplayGraphic LCD
Disturbance recorderUp to 20 records
Accuracy classClass 0.5 metering
CaseFlush mount
Time syncSNTPmade to order: IRIG-B / PTP
Cyber-securityRole-based access

BARREL: Bharat Atom Renewable Resources Energy Limited