Distance protection relay, Pro seriesSample
by Jalcore Protection Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Jalcore Protection Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Pro range of distance protection relay by Jalcore covers 4 function options (Overcurrent / earth fault to Transformer differential). Key features: front USB and rear Ethernet ports, breaker failure and trip circuit supervision and event and fault recorder with 1 ms stamps. Used by substation feeders, transformer bays and industrial incomers. Designed and tested to IEC 60255, IEC 61850 and IS 3231. Lead time 3-6 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Jalcore
- Model
- JAL-F42 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 3-6 weeks
- Warranty
- 24 months
- Standards
- IEC 60255, IEC 61850, IS 3231
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| FunctionOvercurrent / earth faultJAL-F42-01 | Function: Overcurrent / earth fault | 1 nos · 3-6 weeks | for verified buyers |
| FunctionMotor protectionJAL-F42-02 | Function: Motor protection | 1 nos · 3-6 weeks | for verified buyers |
| FunctionFeeder protectionJAL-F42-03 | Function: Feeder protection | 1 nos · 8-10 weeks | for verified buyers |
| FunctionTransformer differentialJAL-F42-04 | Function: Transformer differential | 1 nos · 8-10 weeks | for verified buyers |
Specifications
| Function | Overcurrent / earth fault to Transformer differential (see variants) |
|---|---|
| Aux supply | 110 V DCmade to order: 24-250 V DC / 220 V DC |
| CT input | 1 A |
| VT input | 110 V |
| Binary inputs | 16 |
| Output relays | 24made to order: 6 / 12 |
| Communication | Modbusmade to order: IEC 61850 Ed 2 / IEC 60870-5-103 |
| Display | Graphic LCD |
| Disturbance recorder | Up to 20 records |
| Accuracy class | Class 0.5 metering |
| Case | Flush mount |
| Time sync | SNTPmade to order: IRIG-B / PTP |
| Cyber-security | Role-based access |