Compact secondary substation from Jalline, Core 7 series: 3 transformer rating options between 250 kVA and 630 kVA. Highlights: factory assembled and tested, heat dissipation tested and internal arc proof design. Suited to telecom and metro, industrial parks and solar power plants. Designed and tested to IEC 62271-202, IS 1180 and IEC 62271-200. Lead time 6-8 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Jalline
- Model
- JAL-117 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 10 nos
- Lead time
- 6-8 weeks
- Warranty
- 18 months
- Standards
- IEC 62271-202, IS 1180, IEC 62271-200
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- FOR site, freight included
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Transformer rating250 kVAJAL-117-01 | Transformer rating: 250 kVA | 10 nos · 6-8 weeks | for verified buyers |
| Transformer rating500 kVAJAL-117-02 | Transformer rating: 500 kVA | 10 nos · 6-8 weeks | for verified buyers |
| Transformer rating630 kVAJAL-117-03 | Transformer rating: 630 kVA | 10 nos · 6-8 weeks | for verified buyers |
Specifications
| Transformer rating | 250 kVA to 630 kVA (see variants) |
|---|---|
| Primary voltage | 33 kVmade to order: 11 kV / 22 kV |
| Secondary voltage | 0.69 kVmade to order: 0.433 kV |
| HV equipment | Ring main unitmade to order: VCB panel / Fuse switch |
| Transformer type | Oil-immersedmade to order: Cast resin dry |
| LT section | MCCB feedersmade to order: ACB incomer |
| Enclosure | FRPmade to order: Galvanised steel / Concrete |
| Ingress protection | IP54 |
| Internal arc rating | 16 kA 1 s |
| Short-circuit rating | 25 kA |
| Metering | Multifunction meter, CT operated |
| Ventilation | Natural louvres |
| Oil containment | Integrated sump |