The Flex 2 range of unit auxiliary transformer by Jalline covers 5 rating options (100 kVA to 1600 kVA). Highlights: low zero-sequence impedance, suitable for outdoor substation and provides earth reference to ungrounded systems. Used by wind farm collector systems, substation auxiliary supply and industrial networks. Designed and tested to IS 1180, IS 2026 and IEC 60076. Lead time 3-5 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Jalline
- Model
- JAL-C07 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 3-5 weeks
- Warranty
- 18 months
- Standards
- IS 1180, IS 2026, IEC 60076
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating100 kVAJAL-C07-01 | Rating: 100 kVA | 1 nos · 3-5 weeks | for verified buyers |
| Rating315 kVAJAL-C07-02 | Rating: 315 kVA | 1 nos · 3-5 weeks | for verified buyers |
| Rating630 kVAJAL-C07-03 | Rating: 630 kVA | 1 nos · 3-5 weeks | for verified buyers |
| Rating1000 kVAJAL-C07-04 | Rating: 1000 kVA | 1 nos · 8-10 weeks | for verified buyers |
| Rating1600 kVAJAL-C07-05 | Rating: 1600 kVA | 1 nos · 8-10 weeks | for verified buyers |
Specifications
| Rating | 100 kVA to 1600 kVA (see variants) |
|---|---|
| Type | Auxiliary (Dyn11) |
| Primary voltage | 11 kV |
| Secondary voltage | 3.3 kVmade to order: 0.433 kV |
| Short-time rating | 30 s |
| Neutral current | 200 A |
| Cooling | ONANmade to order: Dry AN |
| Vector group | Dyn11 |
| Impedance | 5%made to order: 4% / Low zero-sequence |
| Tap changer | Off-circuit +/- 5% |
| Termination | Cable box |
| Mounting | Plinth |