Catalogue / Gas-based suppression

No photo yet

Gas suppression system for electrical panels, Max seriesSample

by Jhelumfaraday Fire Engineers (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Jhelumfaraday Fire Engineers (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Jhelumfaraday Max gas suppression system for electrical panels, offered in 5 protected volume options from Up to 50 m³ to 1000-3000 m³. Design: pre-discharge alarm and strobe, abort and manual release switches at exits and hydraulic flow calculation with listed software. Typically used for cable vaults in plants, server rooms and data centres and control and relay rooms. Designed and tested to NFPA 2001, ISO 14520 and EN 15004. Lead time 8-12 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Jhelumfaraday
Model
JHE-4F1 series
Listing type
Product
Unit
set
Minimum order
1 set
Lead time
8-12 weeks
Warranty
12 months from commissioning
Standards
NFPA 2001, ISO 14520, EN 15004
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
Ex-works, freight extra at actuals
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Protected volumeUp to 50 m³JHE-4F1-01Protected volume: Up to 50 m³1 set · 8-12 weeksfor verified buyers
Protected volume50-150 m³JHE-4F1-02Protected volume: 50-150 m³1 set · 8-12 weeksfor verified buyers
Protected volume150-400 m³JHE-4F1-03Protected volume: 150-400 m³1 set · 8-12 weeksfor verified buyers
Protected volume400-1000 m³JHE-4F1-04Protected volume: 400-1000 m³1 set · 8-12 weeksfor verified buyers
Protected volume1000-3000 m³JHE-4F1-05Protected volume: 1000-3000 m³1 set · 8-12 weeksfor verified buyers

Specifications

Protected volumeUp to 50 m³ to 1000-3000 m³ (see variants)
AgentCO2made to order: FK-5-1-12 / HFC-227ea / IG-541
Cylinder pressure300 barmade to order: 25 bar / 42 bar
Discharge time10 seconds
DetectionCross-zoned smoke detectors
ReleaseMechanical
PanelGas release control panel with abort and hold
Nozzles360° discharge nozzle
PipingSeamless MS Sch 40
Design concentration4.2%made to order: 40% for IG-541
Sound levelMax 120 dB (discharge)
Cylinder valveSolenoid + pressure switch