Catalogue / Aspirating smoke detection
Aspirating smoke detection (ASD) unit, Volt seriesSample
by Jhelumfaraday Fire Engineers (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Jhelumfaraday Fire Engineers (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Aspirating smoke detection (ASD) unit from Jhelumfaraday, Volt series: 3 coverage options between Up to 500 m² / 2 pipes and Up to 2000 m². Highlights: four alarm levels for graded response, dust-immune with laser detection and remote configuration and event log. Typically used for data centres and control rooms, battery energy storage containers and cable tunnels and galleries. Designed and tested to EN 54-20, NFPA 76 and NFPA 72. Lead time 6-8 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Jhelumfaraday
- Model
- JHE-5C2 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 6-8 weeks
- Warranty
- 24 months from supply
- Standards
- EN 54-20, NFPA 76, NFPA 72
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| CoverageUp to 500 m² / 2 pipesJHE-5C2-01 | Coverage: Up to 500 m² / 2 pipes | 2 nos · 6-8 weeks | for verified buyers |
| CoverageUp to 1000 m² / 4 pipesJHE-5C2-02 | Coverage: Up to 1000 m² / 4 pipes | 2 nos · 6-8 weeks | for verified buyers |
| CoverageUp to 2000 m²JHE-5C2-03 | Coverage: Up to 2000 m² | 2 nos · 6-8 weeks | for verified buyers |
Specifications
| Coverage | Up to 500 m² / 2 pipes to Up to 2000 m² (see variants) |
|---|---|
| Sensitivity | Class A (very high)made to order: Class B / Class C |
| Detection | Laser light scattering |
| Alarm levels | Alert, Action, Fire 1, Fire 2 |
| Pipe network | Up to 100 mmade to order: Up to 400 m |
| Sampling holes | Up to 40 |
| Airflow monitoring | Yes, with fault alarm |
| Relays | 5 |
| Communication | Ethernetmade to order: RS-485 / Modbus |
| Power supply | 24 VDC |
| Dust filter | Replaceable |
| Operating temperature | -10 to 39 °C |
| Approval | UL 268 |