Catalogue / Surge arresters (station class)
Line surge arrester with disconnector, Plus seriesSample
by Jhelum Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Jhelum Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Line surge arrester with disconnector from Jhelum, Plus series: 6 system voltage options between 12 kV and 420 kV. Design: silicone rubber housing, pressure relief for safe failure and gapless zinc oxide blocks. Suited to substations, transmission lines and solar plants. Designed and tested to IEC 60099-4, IS 3070 (Part 3) and IEC 60099-5. Lead time 8-10 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Jhelum
- Model
- JHE-EE7 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 10 nos
- Lead time
- 8-10 weeks
- Warranty
- 36 months
- Standards
- IEC 60099-4, IS 3070 (Part 3), IEC 60099-5
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- Door delivery in metro cities
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage12 kVJHE-EE7-01 | System voltage: 12 kV | 10 nos · 8-10 weeks | for verified buyers |
| System voltage36 kVJHE-EE7-02 | System voltage: 36 kV | 10 nos · 8-10 weeks | for verified buyers |
| System voltage72.5 kVJHE-EE7-03 | System voltage: 72.5 kV | 10 nos · 8-10 weeks | for verified buyers |
| System voltage145 kVJHE-EE7-04 | System voltage: 145 kV | 10 nos · 8-10 weeks | for verified buyers |
| System voltage245 kVJHE-EE7-05 | System voltage: 245 kV | 10 nos · 8-10 weeks | for verified buyers |
| System voltage420 kVJHE-EE7-06 | System voltage: 420 kV | 10 nos · 8-10 weeks | for verified buyers |
Specifications
| System voltage | 12 kV to 420 kV (see variants) |
|---|---|
| Rated voltage | 330 kV |
| Nominal discharge current | 10 kA |
| Line discharge class | Class 3 |
| Housing | Porcelain |
| Pressure relief class | 63 kA |
| Creepage | 31 mm/kV |
| Energy capability | 7 kJ/kV |
| Counter | With leakage current indicator |
| Mounting | Linemade to order: Pedestal |
| Base insulator | Included |
| Disconnector | Optional |
| Ambient | -40 to 60 deg C |