Catalogue / Gas-insulated switchgear (GIS)
GIS with integrated CT and VT, Core seriesSample
by Jhelum Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Jhelum Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Jhelum Core GIS with integrated CT and VT, offered in 5 system voltage options from 36 kV to 420 kV. Design: compact footprint, up to 90% saving, UHF partial discharge sensors and suitable for indoor and outdoor. Typically used for urban substations, renewable pooling stations and offshore and hilly regions. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 40-52 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Jhelum
- Model
- JHE-0F3 series
- Listing type
- Product
- Unit
- bay
- Minimum order
- 2 bay
- Lead time
- 40-52 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-203, IEC 62271-1, IEC 62271-100
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- FOR site, freight included
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVJHE-0F3-01 | System voltage: 36 kV | 2 bay · 40-52 weeks | for verified buyers |
| System voltage72.5 kVJHE-0F3-02 | System voltage: 72.5 kV | 2 bay · 40-52 weeks | for verified buyers |
| System voltage145 kVJHE-0F3-03 | System voltage: 145 kV | 2 bay · 40-52 weeks | for verified buyers |
| System voltage245 kVJHE-0F3-04 | System voltage: 245 kV | 2 bay · 40-52 weeks | for verified buyers |
| System voltage420 kVJHE-0F3-05 | System voltage: 420 kV | 2 bay · 40-52 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 420 kV (see variants) |
|---|---|
| Rated current | 2500 Amade to order: 1250 A / 3150 A / 4000 A |
| Short-circuit current | 50 kA |
| Configuration | Double busmade to order: Single bus / Ring bus |
| Enclosure | Steel |
| Gas | Clean air |
| Bay width | 800 mmmade to order: 1200 mm / 2500 mm |
| Operating mechanism | Motormade to order: Spring |
| Partial discharge monitoring | UHF sensors |
| Control | Local control cubicle with BCU |
| Gas leakage | < 0.1% per year |
| Earth switches | Maintenance + fast acting |
| Interlocks | Mechanical and electrical |