Catalogue / Hybrid & dead-tank switchgear
Dead-tank circuit breaker with CTs, Eco seriesSample
by Jhelumtesla HV Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Jhelumtesla HV Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Jhelumtesla Eco dead-tank circuit breaker with CTs, offered in 4 system voltage options from 72.5 kV to 420 kV. Highlights: seismic qualified, ideal for pollution-prone sites and quick commissioning. Typically used for brownfield bay additions, seismic zones and pollution and coastal areas. Designed and tested to IEC 62271-100, IEC 62271-108 and IEC 62271-1. Lead time 28-36 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Jhelumtesla
- Model
- JHE-FD3 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 28-36 weeks
- Warranty
- 24 months
- Standards
- IEC 62271-100, IEC 62271-108, IEC 62271-1
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- FOR nearest railhead
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage72.5 kVJHE-FD3-01 | System voltage: 72.5 kV | 5 nos · 28-36 weeks | for verified buyers |
| System voltage145 kVJHE-FD3-02 | System voltage: 145 kV | 5 nos · 28-36 weeks | for verified buyers |
| System voltage245 kVJHE-FD3-03 | System voltage: 245 kV | 5 nos · 28-36 weeks | for verified buyers |
| System voltage420 kVJHE-FD3-04 | System voltage: 420 kV | 5 nos · 28-36 weeks | for verified buyers |
Specifications
| System voltage | 72.5 kV to 420 kV (see variants) |
|---|---|
| Concept | Hybridmade to order: Dead tank / Compact |
| Rated current | 3150 Amade to order: 2000 A / 4000 A |
| Breaking current | 40 kAmade to order: 31.5 kA / 50 kA |
| Gas | SF6-freemade to order: SF6 |
| Integrated CT | Yes, up to 5 cores |
| Integrated disconnector | Yesmade to order: No |
| Integrated earth switch | Yes |
| Mechanism | Spring |
| Insulation | Air outdoor bushings |
| Footprint saving | 50-70% |
| Operating temp | -30 to 50 deg C |
| Monitoring | Gas density, operation counter |