Catalogue / SF6 circuit breakers
SF6 dead tank circuit breaker, Core seriesSample
by Jhelumtesla HV Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Jhelumtesla HV Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Core range of SF6 dead tank circuit breaker by Jhelumtesla covers 6 system voltage options (36 kV to 800 kV). Design: type tested at KEMA or CPRI, corrosion-proof control cabinet and point-on-wave controller option. Suited to grid substations, generator bays and transmission lines. Designed and tested to IEC 62271-100, IS 13118 and IEC 62271-1. Lead time 12-16 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Jhelumtesla
- Model
- JHE-EB6 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 10 nos
- Lead time
- 12-16 weeks
- Warranty
- 30 months from supply
- Standards
- IEC 62271-100, IS 13118, IEC 62271-1
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- Door delivery in metro cities
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVJHE-EB6-01 | System voltage: 36 kV | 10 nos · 12-16 weeks | for verified buyers |
| System voltage72.5 kVJHE-EB6-02 | System voltage: 72.5 kV | 10 nos · 12-16 weeks | for verified buyers |
| System voltage145 kVJHE-EB6-03 | System voltage: 145 kV | 10 nos · 12-16 weeks | for verified buyers |
| System voltage245 kVJHE-EB6-04 | System voltage: 245 kV | 10 nos · 12-16 weeks | for verified buyers |
| System voltage420 kVJHE-EB6-05 | System voltage: 420 kV | 10 nos · 24-30 weeks | for verified buyers |
| System voltage800 kVJHE-EB6-06 | System voltage: 800 kV | 10 nos · 24-30 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 800 kV (see variants) |
|---|---|
| Rated current | 4000 A |
| Breaking current | 31.5 kAmade to order: 25 kA / 40 kA / 50 kA |
| Operating mechanism | Spring-spring |
| Operation | 3-pole |
| Interrupter | Single break |
| SF6 pressure | 0.6 MPa abs |
| Duty cycle | O-0.3s-CO-3min-CO |
| Close time | < 100 ms |
| Insulator | Porcelainmade to order: Composite |
| Auxiliary supply | 220 V DC |
| Creepage | 25 mm/kVmade to order: 31 mm/kV |
| Mechanical endurance | M2 |