Catalogue / Power system studies (load flow, short circuit, grid code)
Load flow and short-circuit study, Neo seriesSample
by Kakatiyaojas Logistics (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kakatiyaojas Logistics (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Kakatiyaojas Neo load flow and short-circuit study, offered in 4 network scale options from 33 kV plant to 220 kV system. Key features: PSS/E and PSCAD model support, fault level verification of switchgear and reports for GNA/connectivity application. Suited to utilities and consultants, industrial plants adding generation and renewable developers seeking connectivity. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation 2-6 weeks; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kakatiyaojas
- Model
- KAK-464 series
- Listing type
- Service
- Unit
- report
- Minimum order
- 1 report
- Lead time
- 2-6 weeks
- Warranty
- Revision for utility comments
- Standards
- CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Network scale33 kV plantKAK-464-01 | Network scale: 33 kV plant | 1 report · 2-6 weeks | on quote |
| Network scale66 kV systemKAK-464-02 | Network scale: 66 kV system | 1 report · 2-6 weeks | on quote |
| Network scale132 kV systemKAK-464-03 | Network scale: 132 kV system | 1 report · 2-6 weeks | on quote |
| Network scale220 kV systemKAK-464-04 | Network scale: 220 kV system | 1 report · 2-6 weeks | on quote |
Specifications
| Network scale | 33 kV plant to 220 kV system (see variants) |
|---|---|
| Study type | Dynamic and transient |
| Software | ETAPmade to order: PSS/E / DIgSILENT PowerFactory |
| Model data | Client single line diagram and data |
| Deliverables | Model files and relay settings |
| Grid code checks | Voltage and reactive power capability |
| Review | Utility submission support |
| Scenarios | Multiple dispatch cases |
| Team | Power system engineermade to order: Lead plus modelling specialist |
| Turnaround | 4-6 weeksmade to order: 2-3 weeks |
| Validation | Compared with measured datamade to order: Peer review |