Catalogue / Substation construction
Pooling substation for renewable projects, Max seriesSample
by Kakatiyasetu Projects (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kakatiyasetu Projects (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Max service of pooling substation for renewable projects by Kakatiyasetu covers 4 voltage class options (66 kV to 400 kV). Design: control room cabling and glanding, battery and DC system installation and pre-commissioning tests before CEIG visit. Used by data centre power infrastructure, renewable pooling stations and state utility augmentation. Delivered in line with CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1 and IS 3043 (Earthing). Mobilisation Engineering in 4-6 weeks; serves East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kakatiyasetu
- Model
- KAK-DC6 series
- Listing type
- Service
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- Engineering in 4-6 weeks
- Warranty
- Defect liability 24 months
- Standards
- CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1, IS 3043 (Earthing)
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage class66 kVKAK-DC6-01 | Voltage class: 66 kV | 1 bay · Engineering in 4-6 weeks | on quote |
| Voltage class132 kVKAK-DC6-02 | Voltage class: 132 kV | 1 bay · Engineering in 4-6 weeks | on quote |
| Voltage class220 kVKAK-DC6-03 | Voltage class: 220 kV | 1 bay · Execution 6-15 months | on quote |
| Voltage class400 kVKAK-DC6-04 | Voltage class: 400 kV | 1 bay · Execution 6-15 months | on quote |
Specifications
| Voltage class | 66 kV to 400 kV (see variants) |
|---|---|
| Type | Outdoor AISmade to order: Indoor GIS / Hybrid GIS |
| Scope | Full turnkey |
| Transformers | Up to 50 MVAmade to order: Up to 160 MVA / Up to 315 MVA |
| Earthing | Copper-bonded rodsmade to order: GI flat grid with ground rods |
| Bay count | 6-10 baysmade to order: 2-4 bays |
| Protection scheme | Main-1 and Main-2 relaysmade to order: Numerical busbar protection |
| SCADA and communication | IEC 61850 compliant |
| Statutory | STU charging approvalmade to order: CEIG inspection support |
| Duration | 6-9 monthsmade to order: 12-15 months |
| Payment terms | Percentage on supply, erection |