Catalogue / Instrument transformers (CT, PT, CVT)
Capacitor voltage transformer, Volt seriesSample
by Kakatiya Transformer Works (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kakatiya Transformer Works (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Capacitor voltage transformer from Kakatiya, Volt series: 6 system voltage options between 11 kV and 400 kV. Key features: corrosion-resistant stainless steel box, tan-delta tap for testing and composite housing for contamination. Suited to substation metering, industrial incomers and revenue metering by discoms. Designed and tested to IS 2705, IS 3156 and IEC 61869-2. Lead time 4-6 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kakatiya
- Model
- KAK-C46 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 4-6 weeks
- Warranty
- 24 months from commissioning
- Standards
- IS 2705, IS 3156, IEC 61869-2
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- Door delivery in metro cities
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage11 kVKAK-C46-01 | System voltage: 11 kV | 5 nos · 4-6 weeks | on quote |
| System voltage33 kVKAK-C46-02 | System voltage: 33 kV | 5 nos · 4-6 weeks | on quote |
| System voltage66 kVKAK-C46-03 | System voltage: 66 kV | 5 nos · 4-6 weeks | on quote |
| System voltage132 kVKAK-C46-04 | System voltage: 132 kV | 5 nos · 4-6 weeks | on quote |
| System voltage220 kVKAK-C46-05 | System voltage: 220 kV | 5 nos · 10-14 weeks | on quote |
| System voltage400 kVKAK-C46-06 | System voltage: 400 kV | 5 nos · 10-14 weeks | on quote |
Specifications
| System voltage | 11 kV to 400 kV (see variants) |
|---|---|
| Type | Combined CT-PT |
| Ratio | 1200-2400/1 Amade to order: 100-200/1 A / 400-800/1 A / 132 kV/110 V |
| Accuracy class | 0.2S |
| Burden | 15 VA |
| Cores | 5 |
| Short-time current | 31.5 kA 1smade to order: 25 kA 1s / 40 kA 1s |
| Insulation | Epoxy castmade to order: Oil-paper / SF6 gas |
| Housing | Porcelainmade to order: Silicone composite |
| Creepage | 31 mm/kV |
| Mounting | Indoor |
| Secondary terminals | Stainless steel |
| Burden type | Metering |