The Elite range of containerised mobile substation by Kakatiya covers 4 transformer rating options (5 MVA to 31.5 MVA). Key features: pre-wired and tested on a trailer, bay-extension and maintenance outage cover and suitable for road transport within weight limits. Typically used for mining sites, temporary construction power and discom emergency backup. Designed and tested to IEC 62271-202, IS 2026 and IEC 60076. Lead time 30-40 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Kakatiya
Model
KAK-8E2 series
Listing type
Product
Unit
nos
Minimum order
2 nos
Lead time
30-40 weeks
Warranty
36 months
Standards
IEC 62271-202, IS 2026, IEC 60076
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Packaging
Corrugated box on pallet
Delivery terms
Door delivery in metro cities
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating5 MVAKAK-8E2-01Transformer rating: 5 MVA2 nos · 30-40 weeksfor verified buyers
Transformer rating10 MVAKAK-8E2-02Transformer rating: 10 MVA2 nos · 30-40 weeksfor verified buyers
Transformer rating20 MVAKAK-8E2-03Transformer rating: 20 MVA2 nos · 30-40 weeksfor verified buyers
Transformer rating31.5 MVAKAK-8E2-04Transformer rating: 31.5 MVA2 nos · 30-40 weeksfor verified buyers

Specifications

Transformer rating5 MVA to 31.5 MVA (see variants)
Primary voltage220 kV
Secondary voltage33 kV
ChassisContainer
Primary switchgearAIS disconnector and breaker
Secondary switchgearIndoor VCB panel
Control and relayNumerical relays
Fire protectionDetection and extinguisher
Auxiliary supplyDC battery + DG
Transport weightUp to 45 t
Setup time< 4 hoursmade to order: < 24 hours
GroundingMobile earthing kit
Cable reelIncluded