Catalogue / SCADA, RTU & plant controllers

No photo yet

Substation SCADA gateway, Volt 6 seriesSample

by Kalinga SCADA Systems (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Kalinga SCADA Systems (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Volt 6 range of substation SCADA gateway by Kalinga covers 4 i/O capacity options (32 DI / 16 DO / 8 AI to 256 I/O modular). Highlights: sequence of events recording at 1 ms resolution, secure communication with TLS and role-based access and multi-protocol gateway with protocol conversion. Used by grid substation automation, solar and wind plant telemetry to SLDC and utility distribution automation. Designed and tested to IEC 60870-5-104, IEC 61850 and IEC 60255. Lead time 8-10 weeks; delivers to South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Kalinga
Model
KAL-261 series
Listing type
Product
Unit
nos
Minimum order
5 nos
Lead time
8-10 weeks
Warranty
24 months from commissioning
Standards
IEC 60870-5-104, IEC 61850, IEC 60255
Delivers to
South India
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
FOR site, freight included
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
I/O capacity32 DI / 16 DO / 8 AIKAL-261-01I/O capacity: 32 DI / 16 DO / 8 AI5 nos · 8-10 weeksfor verified buyers
I/O capacity64 DI / 32 DO / 16 AIKAL-261-02I/O capacity: 64 DI / 32 DO / 16 AI5 nos · 8-10 weeksfor verified buyers
I/O capacity128 I/O modularKAL-261-03I/O capacity: 128 I/O modular5 nos · 8-10 weeksfor verified buyers
I/O capacity256 I/O modularKAL-261-04I/O capacity: 256 I/O modular5 nos · 8-10 weeksfor verified buyers

Specifications

I/O capacity32 DI / 16 DO / 8 AI to 256 I/O modular (see variants)
ProtocolsIEC 61850 servermade to order: IEC 60870-5-101/104 / Modbus RTU/TCP / DNP3
CPUARM Cortex-A9
Power supply48 VDC
Operating temperature-25 to 70 °C
Analog input0-10 Vmade to order: 4-20 mA / CT/PT direct
Ethernet ports4 with redundancy (PRP/HSR)made to order: 2
Serial ports2 x RS-485
Time syncGPS PPS
Event resolution1 ms SOE
RedundancySingle CPU
MountingDIN rail
Ingress protectionIP30made to order: IP20

BARREL: Bharat Atom Renewable Resources Energy Limited