Catalogue / Distribution transformer monitoring units (DTMU)
Distribution transformer monitoring unit (DTMU), Smart 3 seriesSample
by Kalinga SCADA Systems (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kalinga SCADA Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Distribution transformer monitoring unit (DTMU) from Kalinga, Smart 3 series: 5 DT rating covered options between Up to 63 kVA and 1250-2000 kVA. Design: real-time loading and overload alarms, phase unbalance and neutral current monitoring and remote configuration of thresholds. Used by discom energy audit, transformer failure prevention and theft detection at feeder/DT level. Designed and tested to IS 16444, IS 15959 and IEC 62053-22. Lead time 3-4 weeks; delivers to South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kalinga
- Model
- KAL-B82 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 3-4 weeks
- Warranty
- 24 months from supply
- Standards
- IS 16444, IS 15959, IEC 62053-22
- Delivers to
- South India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| DT rating coveredUp to 63 kVAKAL-B82-01 | DT rating covered: Up to 63 kVA | 1 nos · 3-4 weeks | on quote |
| DT rating covered100-200 kVAKAL-B82-02 | DT rating covered: 100-200 kVA | 1 nos · 3-4 weeks | on quote |
| DT rating covered250-400 kVAKAL-B82-03 | DT rating covered: 250-400 kVA | 1 nos · 3-4 weeks | on quote |
| DT rating covered500-1000 kVAKAL-B82-04 | DT rating covered: 500-1000 kVA | 1 nos · 6-8 weeks | on quote |
| DT rating covered1250-2000 kVAKAL-B82-05 | DT rating covered: 1250-2000 kVA | 1 nos · 6-8 weeks | on quote |
Specifications
| DT rating covered | Up to 63 kVA to 1250-2000 kVA (see variants) |
|---|---|
| Measurement | V, I, kW, kVA, PF, THD |
| Accuracy class | 0.5Smade to order: 1.0 |
| CT input | Split-core CT 100/5 A |
| Communication | NB-IoT |
| Oil temperature sensor | PT100 with probemade to order: Not included |
| Alarms | Overload, unbalance, phase failure, low voltage |
| Protocol | Modbus |
| Data interval | 15 min |
| Power supply | Aux 230 V |
| Enclosure | IP65 polycarbonate |
| Load survey | 60 days internal |