Catalogue / Distribution transformer monitoring units (DTMU)
DTMU with LT CTs and sensors, Xtra seriesSample
by Kalinga SCADA Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kalinga SCADA Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
DTMU with LT CTs and sensors from Kalinga, Xtra series: 3 DT rating covered options between 250-400 kVA and 1250-2000 kVA. Highlights: remote configuration of thresholds, power failure last-gasp message and interface to discom SCADA/AMI platform. Typically used for RDSS distribution loss reduction, discom energy audit and transformer failure prevention. Designed and tested to IS 16444, IS 15959 and IEC 62053-22. Lead time 6-8 weeks; delivers to South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kalinga
- Model
- KAL-404 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 6-8 weeks
- Warranty
- 36 months from supply
- Standards
- IS 16444, IS 15959, IEC 62053-22
- Delivers to
- South India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| DT rating covered250-400 kVAKAL-404-01 | DT rating covered: 250-400 kVA | 1 nos · 6-8 weeks | for verified buyers |
| DT rating covered500-1000 kVAKAL-404-02 | DT rating covered: 500-1000 kVA | 1 nos · 6-8 weeks | for verified buyers |
| DT rating covered1250-2000 kVAKAL-404-03 | DT rating covered: 1250-2000 kVA | 1 nos · 6-8 weeks | for verified buyers |
Specifications
| DT rating covered | 250-400 kVA to 1250-2000 kVA (see variants) |
|---|---|
| Measurement | V, I, kW, kVA, PF, THD |
| Accuracy class | 0.5S |
| CT input | Split-core CT 100/5 Amade to order: Split-core CT 600/5 A / CT 1000/1 A |
| Communication | RF mesh |
| Oil temperature sensor | PT100 with probemade to order: Not included |
| Alarms | Overload, unbalance, phase failure, low voltage |
| Protocol | MQTT |
| Data interval | 15 min |
| Power supply | Aux 230 Vmade to order: Self-powered from LT (3-ph) |
| Enclosure | IP65 polycarbonate |
| Load survey | 60 days internal |