Catalogue / Active harmonic filters
Active harmonic filter 4-wire, Neo 5 seriesSample
by Kamrupanant Power Quality (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kamrupanant Power Quality (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Neo 5 range of active harmonic filter 4-wire by Kamrupanant covers 3 compensation current options (100 A to 200 A). Design: real-time harmonic current cancellation, parallel modular scaling to higher currents and automatic adaptation to varying load. Used by EV charging and solar inverter locations, data centres and IT parks and plants with large VFD and UPS loads. Designed and tested to IEEE 519, IEC 61000-3-12 and IEC 61000-6-2. Lead time 6-8 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kamrupanant
- Model
- KAM-F52 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 6-8 weeks
- Warranty
- 24 months from commissioning
- Standards
- IEEE 519, IEC 61000-3-12, IEC 61000-6-2
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- Door delivery in metro cities
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Compensation current100 AKAM-F52-01 | Compensation current: 100 A | 1 nos · 6-8 weeks | for verified buyers |
| Compensation current150 AKAM-F52-02 | Compensation current: 150 A | 1 nos · 6-8 weeks | for verified buyers |
| Compensation current200 AKAM-F52-03 | Compensation current: 200 A | 1 nos · 6-8 weeks | for verified buyers |
Specifications
| Compensation current | 100 A to 200 A (see variants) |
|---|---|
| Voltage | 3-ph 480 Vmade to order: 3-ph 415 V / 690 V |
| Wires | 4-wire |
| Harmonic order | 2nd to 25thmade to order: 2nd to 50th |
| Response time | < 100 µs samplingmade to order: < 20 ms |
| Reactive compensation | Yes, selectable |
| Efficiency | > 97% |
| CT type | Closed loop 5 Amade to order: Split-core Rogowski |
| Cooling | Forced air |
| Communication | RS-485 |
| Parallel operation | Up to 6 units |
| Enclosure | IP54made to order: IP20 / IP31 |