Catalogue / Substation construction
Pooling substation for renewable projects, Elite 4 seriesSample
by Kamrup Projects (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kamrup Projects (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Kamrup Elite 4 pooling substation for renewable projects, offered in 5 voltage class options from 33 kV to 400 kV. Key features: fire protection and oil soak pits, full documentation pack and as-built and earth grid designed for fault level and soil resistivity. Suited to industrial captive substations, renewable pooling stations and state utility augmentation. Delivered in line with CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1 and IS 3043 (Earthing). Mobilisation Execution 6-15 months; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kamrup
- Model
- KAM-DC5 series
- Listing type
- Service
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- Execution 6-15 months
- Warranty
- Defect liability 24 months
- Standards
- CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1, IS 3043 (Earthing)
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage class33 kVKAM-DC5-01 | Voltage class: 33 kV | 1 bay · Execution 6-15 months | on quote |
| Voltage class66 kVKAM-DC5-02 | Voltage class: 66 kV | 1 bay · Execution 6-15 months | on quote |
| Voltage class132 kVKAM-DC5-03 | Voltage class: 132 kV | 1 bay · Execution 6-15 months | on quote |
| Voltage class220 kVKAM-DC5-04 | Voltage class: 220 kV | 1 bay · Execution 6-15 months | on quote |
| Voltage class400 kVKAM-DC5-05 | Voltage class: 400 kV | 1 bay · Execution 6-15 months | on quote |
Specifications
| Voltage class | 33 kV to 400 kV (see variants) |
|---|---|
| Type | Outdoor AISmade to order: Indoor GIS / Hybrid GIS |
| Scope | Civil and structuralmade to order: Erection and testing / Full turnkey |
| Transformers | Up to 160 MVAmade to order: Up to 50 MVA / Up to 315 MVA |
| Earthing | GI flat grid with ground rodsmade to order: Copper-bonded rods |
| Bay count | 2-4 baysmade to order: 6-10 bays |
| Protection scheme | Main-1 and Main-2 relaysmade to order: Numerical busbar protection |
| SCADA and communication | IEC 60870-5-104made to order: IEC 61850 compliant |
| Statutory | CEIG inspection support |
| Duration | 12-15 months |
| Payment terms | Milestone: 10/70/10/10made to order: Percentage on supply, erection |