Catalogue / Line monitoring (DLR, fault passage indicators)
Dynamic line rating sensor, Core seriesSample
by Kanchi Line Hardware (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kanchi Line Hardware (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Core range of dynamic line rating sensor by Kanchi covers 5 voltage class options (33 kV to 400 kV). Highlights: remote fault location, reduces patrolling, integrates with SCADA / OMS and live-line installation with a hot stick. Typically used for renewable evacuation lines, overhead feeders with heavy fault history and discom feeders. Designed and tested to IEEE 738, CIGRE TB 601 and IEC 60255-151. Lead time 3-5 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kanchi
- Model
- KAN-437 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 3-5 weeks
- Warranty
- 36 months
- Standards
- IEEE 738, CIGRE TB 601, IEC 60255-151
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- FOR site, freight included
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage class33 kVKAN-437-01 | Voltage class: 33 kV | 1 nos · 3-5 weeks | on quote |
| Voltage class66 kVKAN-437-02 | Voltage class: 66 kV | 1 nos · 3-5 weeks | on quote |
| Voltage class132 kVKAN-437-03 | Voltage class: 132 kV | 1 nos · 3-5 weeks | on quote |
| Voltage class220 kVKAN-437-04 | Voltage class: 220 kV | 1 nos · 8-10 weeks | on quote |
| Voltage class400 kVKAN-437-05 | Voltage class: 400 kV | 1 nos · 8-10 weeks | on quote |
Specifications
| Voltage class | 33 kV to 400 kV (see variants) |
|---|---|
| Device | Fault passage indicatormade to order: DLR sensor / Sag monitor |
| Measured | Sagmade to order: Conductor temperature / Current / Weather |
| Accuracy | +/- 1 deg C |
| Communication | Satellite |
| Power source | Line current harvestingmade to order: Solar + battery |
| Mounting | Live-line clamp-on |
| Fault detection | Short-circuit, earth fault |
| Reporting interval | 10 minmade to order: 1 min |
| Enclosure | IP67 |
| Weight | 1 kgmade to order: 2.5 kg |
| Software | Cloud dashboard |
| Integration | IEC 60870-5-104, Modbus |