Catalogue / Switchgear & breaker spares
Spring charging motor, Ultra seriesSample
by Kanchi Spare Parts (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kanchi Spare Parts (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Spring charging motor from Kanchi, Ultra series: 5 rated voltage options between 12 kV and 72.5 kV. Design: interchangeable with original design, vacuum integrity certificate and short lead from stock. Suited to planned overhauls, utility maintenance and panel shutdown repair. Designed and tested to IEC 62271-100, IEC 62271-102 and IS 13118. Lead time 1-2 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kanchi
- Model
- KAN-F01 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 1-2 weeks
- Warranty
- 12 months from supply
- Standards
- IEC 62271-100, IEC 62271-102, IS 13118
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rated voltage12 kVKAN-F01-01 | Rated voltage: 12 kV | 1 nos · 1-2 weeks | for verified buyers |
| Rated voltage17.5 kVKAN-F01-02 | Rated voltage: 17.5 kV | 1 nos · 1-2 weeks | for verified buyers |
| Rated voltage24 kVKAN-F01-03 | Rated voltage: 24 kV | 1 nos · 1-2 weeks | for verified buyers |
| Rated voltage36 kVKAN-F01-04 | Rated voltage: 36 kV | 1 nos · 4-8 weeks | for verified buyers |
| Rated voltage72.5 kVKAN-F01-05 | Rated voltage: 72.5 kV | 1 nos · 4-8 weeks | for verified buyers |
Specifications
| Rated voltage | 12 kV to 72.5 kV (see variants) |
|---|---|
| Component | Mechanism |
| Rated current | 630 Amade to order: 1250 A / 2000 A / 3150 A |
| Short circuit rating | 25 kAmade to order: 31.5 kA / 40 kA |
| Mechanical life | 10000 operationsmade to order: 30000 operations |
| Coil voltage | 110 V DCmade to order: 220 V DC |
| Motor voltage | 230 V AC |
| Fits make | As per breaker nameplate |
| Packing | Foam lined box |
| Testing | Routine tested |
| Origin | OEM |