Catalogue / Aspirating smoke detection
High-sensitivity smoke detection for data centres, Edge 6 seriesSample
by Kavachcore Fire Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kavachcore Fire Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Kavachcore Edge 6 high-sensitivity smoke detection for data centres, offered in 4 coverage options from Up to 250 m² / 1 pipe to Up to 2000 m². Design: remote configuration and event log, dust-immune with laser detection and fault-monitored pipe network and airflow. Used by cable tunnels and galleries, high-bay warehouses and data centres and control rooms. Designed and tested to EN 54-20, NFPA 76 and NFPA 72. Lead time 6-8 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kavachcore
- Model
- KAV-5A9 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 6-8 weeks
- Warranty
- 24 months from supply
- Standards
- EN 54-20, NFPA 76, NFPA 72
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| CoverageUp to 250 m² / 1 pipeKAV-5A9-01 | Coverage: Up to 250 m² / 1 pipe | 1 nos · 6-8 weeks | for verified buyers |
| CoverageUp to 500 m² / 2 pipesKAV-5A9-02 | Coverage: Up to 500 m² / 2 pipes | 1 nos · 6-8 weeks | for verified buyers |
| CoverageUp to 1000 m² / 4 pipesKAV-5A9-03 | Coverage: Up to 1000 m² / 4 pipes | 1 nos · 6-8 weeks | for verified buyers |
| CoverageUp to 2000 m²KAV-5A9-04 | Coverage: Up to 2000 m² | 1 nos · 6-8 weeks | for verified buyers |
Specifications
| Coverage | Up to 250 m² / 1 pipe to Up to 2000 m² (see variants) |
|---|---|
| Sensitivity | Class C |
| Detection | Laser light scattering |
| Alarm levels | Alert, Action, Fire 1, Fire 2 |
| Pipe network | Up to 400 m |
| Sampling holes | Up to 40 |
| Airflow monitoring | Yes, with fault alarm |
| Relays | 5 |
| Communication | RS-485made to order: Modbus / Ethernet |
| Power supply | 24 VDC |
| Dust filter | Replaceable |
| Operating temperature | -10 to 39 °C |
| Approval | EN 54-20 |