Catalogue / Bus ducts

No photo yet

Air-insulated busduct for transformer connection, Max seriesSample

by Kavachtek Switchboards (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Kavachtek Switchboards (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Max range of air-insulated busduct for transformer connection by Kavachtek covers 6 rating options (400 A to 3200 A). Key features: bends, tees, flanged ends and reducers available, plug-in tap-off units with interlocked isolators and fire-resistant barrier option at slab crossings. Suited to high-rise buildings, transformer to PCC links and data centres. Designed and tested to IEC 61439-6, IS 8623 (Part 2) and IEC 61439-1. Lead time 4-6 weeks; delivers to South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Kavachtek
Model
KAV-333 series
Listing type
Product
Unit
m
Minimum order
1 m
Lead time
4-6 weeks
Warranty
24 months from supply
Standards
IEC 61439-6, IS 8623 (Part 2), IEC 61439-1
Delivers to
South India
GST rate
18 %
Country of origin
India
Packaging
Corrugated box on pallet
Delivery terms
FOR nearest railhead
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Rating400 AKAV-333-01Rating: 400 A1 m · 4-6 weeksfor verified buyers
Rating630 AKAV-333-02Rating: 630 A1 m · 4-6 weeksfor verified buyers
Rating1000 AKAV-333-03Rating: 1000 A1 m · 4-6 weeksfor verified buyers
Rating1600 AKAV-333-04Rating: 1600 A1 m · 4-6 weeksfor verified buyers
Rating2500 AKAV-333-05Rating: 2500 A1 m · 8-10 weeksfor verified buyers
Rating3200 AKAV-333-06Rating: 3200 A1 m · 8-10 weeksfor verified buyers

Specifications

Rating400 A to 3200 A (see variants)
ConductorCopper
Rated voltage415 Vmade to order: 690 V / 1000 V
ConstructionSandwich typemade to order: Air-insulated
Short-circuit withstand50 kA/1 smade to order: 65 kA/1 s / 85 kA/1 s / 100 kA/1 s
Degree of protectionIP65
Neutral50% neutralmade to order: 100% neutral / 200% neutral
InsulationClass B epoxymade to order: Class F polyester / PVC sleeved
EnclosureAluminium extrusionmade to order: Galvanised steel / Powder-coated MS
Tap-offPlug-in
Fire barrierNot requiredmade to order: Provided at floor crossing
Expansion unitsProvidedmade to order: Not required
Phases3P4Wmade to order: 3P5W

BARREL: Bharat Atom Renewable Resources Energy Limited